• AUTOMATIC DRAIN SHUT-OFF VALVE
• pH RANGE: 2 - 11
• MANUAL FAST FLUSH VALVE
• REPLACEMENT FILTERS:
• DAILY PRODUCTION RATE = 16.02 GPD
DESCRIPTION ITEM#
• EFFICIENCY RATING
3
= 17.54%
PRE FILTER
51635
• RECOVERY RATING
4
= 37.23%
MEMBRANE
51637
• MAX TDS LEVEL (PPM) = 1400
POST VOC FILTER
51636
• CAPACITY FOR VOC REDUCTION: 225 GALLONS
• OPERATING PSI OF SUPPLY: 40 - 100 PSI (275 - 689 kPa)
• OPERATING TEMPERATURE: 50 - 100
o
F (10 - 38
o
C)
PERFORMANCE DATA SHEET - page 1 of 3
Ultrefiner II - FMV
PREMIUM DRINKING WATER SYSTEM
THE UNIT SHOULD BE INSTALLED IN AN AREA NOT AFFECTED BY
EXTREME HEAT, COLD, OR THE ELEMENTS. THIS SYSTEM MUST BE
INSTALLED IN ACCORDANCE WITH ALL APPLICABLE STATE AND LOCAL
LAWS AND REGULATIONS.
DO NOT USE WITH WATER THAT IS MICROBIOLOGICALLY UNSAFE OR
OF UNKNOWN QUALITY WITHOUT ADEQUATE DISINFECTION BEFORE
OR AFTER THE SYSTEM. SYSTEMS CERTIFIED FOR CYST REDUCTION
MAY BE USED ON DISINFECTED WATER THAT MAY CONTAIN FILTER-
ABLE CYSTS. THE SYSTEM CONTAINS REPLACEMENT COMPONENTS
CRITICAL FOR EFFECTIVE REDUCTION OF contaminant. THE WATER
SHOULD BE TESTED PERIODICALLY (2 TIMES A YEAR MINIMUM) TO
VERIFY THAT THE SYSTEM IS PERFORMING SATISFACTORILY.
REPLACE ULTREFINER II - FMV MEMBRANE CARTRIDGE 24 TO 36
MONTHS AFTER INSTALLATION, DEPENDING ON WATER CONDITIONS.
A WATER TEST FOR TDS REDUCTION IS THE BEST INDICATOR OF
MEMBRANE PERFORMANCE. REPLACE THE PREFILTER AND POST FIL-
TER CARTRIDGES 12 MONTHS AFTER INSTALLATION OR SOONER
DEPENDING ON WATER CONDITIONS.
THE INLET FEED WATER SHOULD BE FREE FROM IRON, MANGANESE,
SULFUR.
NSF CERTIFIED PERFORMANCE DATA, AS SHOWN ON THE
PERFORMANCE DATA SHEET, IS BASED ON OPERATION AT DRAIN
SETTING # 2. CERTIFICATION RESULTS DO NOT APPLY TO OTHER
SETTINGS.
SEE WARRANTY CARD FOR SPECIFIC WARRANTY INFORMATION
NOT APPROVED FOR USE IN CALIFORNIA. PLEASE REQUEST
CALIFORNIA-SPECIFIC LITERATURE FROM YOUR LOCAL RAIN-
SOFT DEALER.
LIST OF contaminant
CONTAMINANT
AVERAGE
INFLUENT
CONCENTRATION
(mg/L)
AVERAGE
EFFLUENT
CONCENTRATION
(mg/L)
AVERAGE PERCENT
REDUCTION
MAXIMUM
EFFLUENT
CONCENTRATION
(mg/L)
ARSENIC
1
0.29
0.002
99.3
0.003
BARIUM
9.5
0.14
98.5
0.35
CADMIUM
0.031
0.0006
98.1
0.0011
CHROMIUM
(HEXAVALENT)
0.3
0.007
97.7
0.013
CHROMIUM
(TRIVALENT)
0.31
0.003
99.0
0.006
COPPER
3.0
0.038
98.7
0.069
CYST
26000
5
>99.99
21
FLUORIDE
8.6
0.39
95.5
0.51
LEAD
0.16
0.003
98.1
0.019
NITRATE/NITRITE
2
32
4.2
87
5.2
RADIUM 226/228
25 pCi/L
5 pCi/L
80
5 pCi/L
SELENIUM
0.1
<0.006
>94.0
<0.006
TDS
750
27
96.4
86
TURBIDITY
11 NTU
0.08 NTU
99.3
0.26 NTU
NSF/ANSI STANDARD 58 TEST CONDITION: 50 ± 3 psi, pH 7.5 ± 0.5, 77 ± 2 ºF
IMPORTANT NOTICE
:
READ THIS PERFORMANCE DATA SHEET AND COMPARE
THE CAPABILITIES OF THIS UNIT WITH YOUR ACTUAL
WATER TREATMENT NEEDS. IT IS RECOMMENDED THAT
BEFORE PURCHASING A WATER TREATMENT UNIT, YOU
HAVE YOUR WATER SUPPLY TESTED TO DETERMINE
YOUR ACTUAL WATER TREATMENT NEEDS.
Model ULTREFINER II - FMV - BNFP, ULTRE-
FINER II - FMV - BNFV, ULTREFINER II - FMV
- CHFP and ULTREFINER II - FMV - CHFV are
tested and certified by NSF International
against NSF/ANSI 58 for the reduction of
claims specified on the performance data
sheet.
This system has been tested according to NSF/ANSI 58 for reduction of the
substances listed below. The concentration of the indicated substances in
water entering the system was reduced to a concentration less than or
equal to the permissible limit for water leaving the system, as specified in
NSF/ANSI 58.
Summary of Contents for Ultrefiner II
Page 47: ...47 NOTAS...