15
SYS TE M SETUP
Units
English / Met ric
Model
EC5 / EC5-CAB
Unit Size
{Size of S ystem }
Media Typ e
V, CV, T, CT
Hardne ss
01-99 grains/ gallon
Iron
0.0 ppm
Time o f Re gen
02:0 0 AM
Start Capa city
30%-80%
Water P ressu re
20 to 1 00 PSI
System Serial #
112 1113
Installa tion Date
00/00/000 0
Tota l Capa city
### Ga llons
Water to Start Regen
## Gall ons
SYS TE M OVE RRIDE S
90% Exha usted Regn
Immediate / Dela yed
Injector Size
00 / 0 / 1
Backwa sh Control
Size s ( 1 thru 10)
Max Sa lt Override
Off (or set ma x leve l)
Regen Days Overrid e
Off / 1 thru 30 Da ys
>
Mod Cycle Times
LED output O ver ride
OFF / O N
MOD CYCLE TIMES
C1 – Brin e Fill
Add 0 to 15 Minutes
C2 – Brin e Make up
120 – 60 Minutes
C3 – Backwa sh
1 – 30 Minutes
C4 – Brin e/S-Rinse
Add 0 to 20 Minutes
C5 – F-Rinse
Add 0 to 10 Minutes
FILTER LINK
Filte r Mode l
Off / EC5-FLT
Filte r S ize
{Size of Filter Syste m}
Filte r Type
H, A, AS, Y, Y Z, R,
Filte r Insta ll Date
00/00/000 0
Filte r Cycle 3 Time
1 to 40 Minutes
Filte r Cycle 4 Time
0 to 60 Minutes
Filte r Cycle 5 Time
1 to 40 Minutes
Filte r Rege n Time
{Calculated Start time}
Filte r Days Se t
1 to 30 Days
Ser vice Re min ders
Off / Time / Volume
Ser vice Intervals
None/Months/Gallons
Time/V olume Re mai n
0 /# Months/# Ga llons
Ser vice Re min der
Reset: No / Y es
AUX ILIARY SETTINGS
Acti vate Aux 1
OFF / 1 / 2 / 3
Acti vate Aux 2
OFF / 1 / 2 / 3
< Drinking Wat er >
Typ e:
None/Ultrefiner/Hydref iner/O the r
Install Date :
00/00/000 0
Ser vice Interval
Off /Time: 6 to 8 4 Mont hs
Ser vice Re ma ining
# Months RES ET:
No / Ye s
< House Filter >
Typ e:
None /Carbon/Neut ralizer/Sedim ent/Ot her
Install Date :
00/00/000 0
Ser vice Interval
Off /Time/Vol: 6 to 8 4 Months 10 K to 99 0K
Gals
Ser vice Re ma ining
# Months / GA LS RESE T:
No / Ye s
< Sys tem 1 >
Typ e:
None /Clean Start/ AirMaster/ UV / Ultra
filte r / Other
Install Date :
00/00/000 0
Ser vice Interval
Off /Time: 6 to 8 4 Mont hs
Ser vice Re ma ining
# Months RES ET:
No / Ye s
< Sys tem 2
Typ e:
None /Clean Start/ AirMaster/ UV / Ultra
filte r / Other
Install Date :
00/00/000 0
Ser vice Interval
Off /Time: 6 to 8 4 Mont hs
Ser vice Re ma ining
# Months RES ET:
No / Ye s
REGEN INFO
>L ast Re gen In fo
>L ast 5 Reg ens
Regen s last 14 Days
#
Regen s last 28 Days
#
Tota l Rege nerations
#
Avg We ekly Salt Used
# lbs
Last Rege n Info L isted:
Date / Time
Tota l G allons before
rege n
Salt lbs Calculated
Cycle 1 thr u 5 Times
Last 5 Re gen Info
Listed:
Date / Time of La st 5
WATER S TATS
Tota l Capa city
## Gall ons
Water To Start Rege n
## Gall ons
Water A va ilable
# Gallo ns
Avg Wa ter pe r Day
# Gallo ns/Day
Water L ast 28 Da ys
## Gall ons
Tota l Water Used
### Ga llons
Service History
Date / Time
Ser vice Ta gs: #, #
List of l ast 4 S ervice Tags
BOARD INFO:
Pro gram Revision
RS-EC5-VER-##
EEP RO M Revisio n
EEP RO M -EC5-VER- ##
DATE TIME:
ALE RT De scription
List of l ast 4 A lerts
DATE TIME:
ALA RM De scription
List of l ast 4 A larms
AUX S ettings
- Setting
(1)
Aux Output S ignal on
duri ng; REGE N Cycles
[3],[4],[5]
Both EC5 and FILTER L INK
- Setting
(2)
Aux Output S ignal on
duri ng: REGE N Cycles
[4]
EC5
- Setting
(3)
Aux Output S ignal on
duri ng: RE GEN Cycles
[3],[4],[5]
FILTER LINK On ly
CONFIGURE SYSTEM MENU
SYSTEM INFO MENU
Additional Systems Menu
USE LEFT & RIGHT
ARRO W
BUTTONS
TO NAVIGATE
BETWEEN
ADDITIONAL
SYSTEMS MENUS
Summary of Contents for EC5 Series
Page 22: ...22 Control Exploded View 1 5 3 4 4 6 11 7 8 8 10 9 14 2 15 12 13...
Page 42: ...Notes...
Page 43: ...43 Notes...