Step 2: Install battery 

(For model QS1 only)

 

Before mounting the unit, install the monitor battery. Remove 
head cover insert (2713) by gently pulling away the insert from 
the head. Unwrap coin battery (2545) and insert into battery slot 
between contacts with + side out. Now re-attach the head cover 
insert (2713), carefully aligning it so that the black button on the 
monitor lines up through the hole on the cover insert.  
 

 

Step 3: Mounting the Unit 

Locate best position for mounting unit undersink near faucet. The higher and closer to the front you mount the 
unit the easier it will be for regular maintenance (see Fig 1). There are 2 mounting bracket screw locations at the 
back of the head. 

Note: Screw holes at bottom should be at least 12 inches up from the base of the 

cabinet (you must allow at least 3 inches of clearance below the cartridges for easy removal)

.  

 
Screw in the 2 screws making sure that the head assembly is level. Note: If wall is too thin to accept screw then 
use round head nuts and bolts (not supplied) to mount head assembly. 

 
 

Step 4: Connecting the faucet

 

Measure the tubing required to connect faucet to the white OUTLET 
Acculink™ fitting (arrow pointing away from the fitting) and cut this 
length from the tubing supplied. Make a straight cut as shown in Fig 4. 

 

NOTE: Use only a sharp knife to cut the tube straight.  
Warning: Angled or rough cuts can cause a water leak. 

 
Slide compression nut (726-0) and compression sleeve (1008-3) onto 
tube and put tube insert (1603) into tube as shown in Fig. 5. Now tighten 
nut securely with a wrench.  
 
Identify the INLET & OUTLET of the unit (Fig 6A). Connect the other end 
of tubing to OUTLET Acculink

TM

 fitting by pushing the tube into the 

fitting until it touches the tube stop and cannot go in any further (Fig. 
6B). Pull tube to confirm secure connection. 

Note: 

To remove tubing 

from the fitting, press the collet in with two fingers while pulling tube out 
Fig 6C). Without pressing the collet, the tubing will stay locked in 
position. 
 

 
 
 
 
 
 
 
 
 

FIG 4 

INLET 

OUTLET 

FIG 6A 

FIG 6B 

FIG 6C 

2713 

FIG 5 

Summary of Contents for Twist QS1

Page 1: ...ndard B483 1 to NSF ANSI Standard 53 for reduction of lead VOC and Cyst e g Cryptosporidium Giardia to NSF ANSI Standard 42 for reduction of chlorine taste odour and to NSF ANSI 372 for low lead requi...

Page 2: ...multi storey buildings over 4 storeys o Do not subject to freezing temperatures with water inside the unit If your unit will not be used in winter or will be subject to freezing temperatures drain un...

Page 3: ...p 1 Mounting the Faucet Faucet may be installed in hole in sink if available or in counter top Note The faucet may also be installed in the sink sprayer hole if available 1 Position faucet on counter...

Page 4: ...embly is level Note If wall is too thin to accept screw then use round head nuts and bolts not supplied to mount head assembly Step 4 Connecting the faucet Measure the tubing required to connect fauce...

Page 5: ...Measure and cut remaining length of plastic tubing to connect saddle valve to INLET AcculinkTM fitting To connect tube to the saddle valve slide compression nut 726 0 and compression sleeve 1008 3 ont...

Page 6: ...turn left and lower it away from head while holding it vertically to retain water Empty the old cartridge in the kitchen sink by holding it upside down and discard Use a dry absorbent cloth or a paper...

Page 7: ...g out These will clear out if you leave the water standing for a few seconds and are harmless After a few days of use the bubbles will slowly clear away The cartridge came undone from the head on it s...

Page 8: ...nt This warranty does NOT cover and is intended to exclude any liability on the part of Envirogard for any incidental damages consequential damages labour charges or any other costs incurred in connec...

Page 9: ...SA B483 1 selon la norme 53 NSF ANSI pour la r duction le plomb le COV les kystes par ex cryptosporidium et giardia selon la norme 42 NSF ANSI effets esth tiques pour la r duction du chlore le go t et...

Page 10: ...u l int rieur du syst me Si vous n utilisez pas votre syst me en hiver ou s il est expos des temp ratures inf rieures 0 C videz le voir la section Entretien pour plus de d tails Ce syst me est destin...

Page 11: ...du robinet Le robinet peut tre install sur le rebord de l vier ou sur le comptoir Remarque le robinet peut aussi tre install dans un trou de douchette le cas ch ant 1 Le robinet doit tre install pr s...

Page 12: ...des crous non compris tape 3 Raccordement du robinet Mesurez la distance entre le robinet et le raccord AcculinkMC de sortie blanc de la t te du filtre puis coupez un bout de tuyau de plastique 1009...

Page 13: ...nstant Mesurez la distance entre la soupape trier et le raccord Acculink d entr e gris et coupez le tuyau la longueur appropri e Glissez l crou 726 0 la bague 1008 3 et le manchon 1603 du raccord comp...

Page 14: ...ant et choisir un produit Remarque Il n est pas n cessaire de couper l eau pour changer les cartouches Pour remplacer la cartouche voir fig 9 Tournez la cartouche d un quart de tour vers la gauche et...

Page 15: ...condes Ce ph nom ne dure pendant quelques jours apr s le remplacement de la cartouche D branchement soudain de la cartouche Caus par une pression d eau excessive ou des coups de b lier dans les tuyaux...

Page 16: ...te garantie Envirogard ne peut tre tenue responsable d aucun dommage indirect y compris les frais de main d oeuvre et tout autre frais d coulant de l achat de l installation de l entretien ou de la r...

Reviews: