background image

Section 3 – Operating Instructions

10

3.4  Chemflo Flow Rates 

The flow rate of the 

Chemflo

 is varied using a duty cycle, so for most of the time the pump does 

not operate. For example, the pump will be ON for 2.5 minutes per 15 minute cycle when it is set to 

99. When the unit is set to 50, the pump will be ON for half the time, i.e. 1.25 minutes per 15 

minute cycle. Refer to the table below. 

The only time that the pump operates continuously is when the control is set to FULL. 

Flow Rates of Dosing Pump when control set to 

99

Tube Size 

Rate per Hour 

Rate per Day 8 hrs*  Duty Cycle                          

Small Tube 

300 mL/Hr 

2400 mL/Day 

2.5 mins ON per 15 mins 

Large Tube 

1000 mL/Hr 

8000 mL/Day 

2.5 mins ON per 15 mins 

* Based on 8 hour pump operation for each day. 

Flow Rates of Dosing Pump when control set to

 FULL

Small Tube 

1.8 L/hr 

 

 

Large Tube 

6.1 L/Hr 

 

 

Flow rates were measured pumping into a pool line at 50 kPa. 

Summary of Contents for Waterco Chemflo 25880

Page 1: ...each day Chemflo 25880 Acid or Chlorine Feeder Manual Date 1 Sep 2007 Version 1 0 Rainbow Pool Products PO Box 2388 Mansfield Qld 4122 Telephone STD 61 7 3849 5385 Facsimile STD 61 7 3849 5384 Email...

Page 2: ...to Dosing Pump 7 2 4 Mount Feeder and Connect to Electrical Supply 8 Section 3 Operating Instructions 9 3 1 Setting the Correct Dose Rate 9 3 2 Setting the Chemflo to OFF 9 3 3 Setting the Chemflo to...

Page 3: ...e an electrical shock resulting in serious injury or death If the power lead becomes damaged the unit must be returned to your dealer or repaired by an authorised person only 1 1 Chemflo Diagram 1 Dos...

Page 4: ...ion Tee 50mm Part No 117901 50 to 40mm reduction bushes x 2 Part No NPRB5040 Peristaltic Pump Input and Output Tube 4m Part No 116360 Drum lid with gland fitting Part No 116362 Tube weight for chemica...

Page 5: ...eight from the bottom of the chemical drums to the dosing pump is 2 metres 4 The mains power leads from the Chemflo and the Pool Pump reach a mains power outlet If the controller is mounted in a wet a...

Page 6: ...nd fit the compression fitting Drill a second 2mm diameter vent hole to avoid suction build up IMPORTANT INFORMATION REGARDING ACID x Always use dilute Hydrochloric Acid x Add 5 Litres of Acid to 20 t...

Page 7: ...ess steel bolts screws or masonary anchors The Chemflo controller MUST be installed in a sheltered location Connect the Chemflo into a suitable power outlet and the Pool Pump into the piggy back power...

Page 8: ...s on a weekly basis to ensure that the water balance is correct It is recommended that you take a sample of your pool water to a pool shop every month for a complete analysis Maintaining all chemical...

Page 9: ...r 15 minute cycle Refer to the table below The only time that the pump operates continuously is when the control is set to FULL Flow Rates of Dosing Pump when control set to 99 Tube Size Rate per Hour...

Page 10: ...er part No 116353 for the Small Tube or part No 116352 for the Large Tube To remove the old Pump Tube 2 3 4 1 IMPORTANT Place the pump suction tubing into a bucket of fresh water Prime the pump by set...

Page 11: ...ever which pulls the pump tube in as it turns After approximately 3 4 of a turn the right hand side compression fitting can be pushed in round side facing in The new pump tube has now been fitted Repl...

Page 12: ...alified electrician check the Chemflo and or Pool Pump power plugs Contact supplier of Pool Pump for service or replacement Display does not light up when power is connected 1 Power plug is not fully...

Page 13: ...d user The provisions of this warranty are not transferable and are in addition to and not in modification of or subtraction from any applicable statutory warranties rights or remedies CONDITIONS OF W...

Page 14: ...blocking the pump s impeller i insect infestation Some three phase pumps are not supplied with thermal overload protection It is the purchaser s responsibility to have this provision installed by appr...

Page 15: ...18 months Labour 1 year Commercial Applications Controller Feeder 1 year Sensor 1 year Labour 1 year WARRANTY LIMITATIONS The provisions of this warranty are not transferable from the original purchas...

Reviews: