7.2.2 No response from data logger when using a
communications peripheral
At the data logger:
1. Make sure the battery has been installed and the power switch set to ON (
(p. 61)).
2. Use a voltmeter to measure the voltage on the 12V and G terminals (
the voltage must be between 9.6 and 16 VDC.
3. Use a voltmeter to measure the voltage on the 5V and G terminals (
(p. 62));
the voltage must be between 4.9 and 5.1 VDC.
4. Make sure the data logger is connected to the communications peripheral, and the
communications peripheral is properly installed and configured (
(p. 35)).
At the computer:
1. Make sure calling software is properly configured (
SmartWeather
,
Maxicom
,
IQ
, etc.).
2. Check the cable(s) between the serial port and the modem. If cables have not been
purchased through Campbell Scientific, check for the following configuration using an ohm
meter:
9-pin to 25-pin serial cable
Computer end Modem end
2
3
3
2
4
20
5
7
3. Make sure the communications device at the computer is properly configured and cabled
4. Call Rain Bird GSP if still no response.
Section 7. Maintenance and troubleshooting
71
Summary of Contents for WS-PRO2
Page 9: ...FIGURE 3 4 WS PRO2 bottom layer Section 3 Initial inspection 5...