PROGRAMMING

F. PROGRAM TRANSMISSION,

REVIEW, AND CHANGE

20

1. PROGRAM TRANSMISSION

1.1 Plug the field transmitter optical connector onto the control
module. If the LCD screen is blank, press the key.
1.2 -  If you have not already done so, enter the program data. 

1.3 - Press                .

1.4 - After transmission is correctly completed, the
transmitter will display this screen. 

1.5 Press              to remove the display

1.6 - Unplug the field transmitter optical connector from the
control module. The module will now automatically operate.

Important :

if the blinking low battery icon is displayed on

the LCD during program transmission, replace the 9V battery
in the TBOS control module. The low battery icon is used
only in control modules marked TBOS.

NOTE :

Make sure the optical connectors are clean and properly

connected to each other. The control module must be equipped
with a fully charged 9V Alkaline battery (Ref. 6LR61).

2. PROGRAM REVIEW AND CHANGE

2.1 - Plug the field transmitter optical connector onto the
control module.

2.2 - If the LCD screen is blank, press the 

➞ 

key.

2.3 - Press the                 key to receive the program data
stored in the control module. You can now review the program
that is in the control module : run time, start times, water
days, station program assignment (A,B,C), "ON/OFF". However,
you cannot consult the current time of day stored in the module.

2.4 - To modify the program data, simply enter the desired
modifications. Press the                   key even if you decide 

not to make any changes. This will synchronize the transmitter
and module clocks.

Important:

if the blinking low battery icon is displayed on

the LCD  during program reception, replace the 9V battery
in the TBOS control module. The low battery icon is used
only in control modules marked TBOS.

TBOS IR Anglais new der 5/11/04 15:20 Page 8

Summary of Contents for TBOS SYSTEM 6LR61

Page 1: ...8 System on off 9 Now Transmitting 10 Transmission problem 11 Replace low battery inthetransmitteriftheiconappears when the key is pressed to turn on the LCD in the TBOS module if the icon appears dur...

Page 2: ...odule battery must be replaced GB 13 Battery life 1 season with 1 top grade 9V alkaline battery type 6AM6 international standard or type 6LR61 European standard VARTA or equivalent not included Low ba...

Page 3: ...and install it vertically above the cord slot Plug in the RJ9 connector on the Infrared cord Install the battery compartment cover and secure it 14 Remove the rubber plug from its location on the left...

Page 4: ...rogram with the key Water days program Start times program Run time station program assignment of each station Irrigation mode On or Off The LCD will display the low battery icon if TBOS module batter...

Page 5: ...ve it Install the battery Install the battery compartment cover and secure it 2 Set Clock 2 A Set current time of day AM PM Time Format If you want time displayed in AM PM hold down the ABC key for 2...

Page 6: ...for shrubs and program C for trees Stations assigned to the same program operate sequentially 2 Option If you assign a station to each program with the same water days start times and run times you wi...

Page 7: ...the program with the ABC key The program selected will appear on the screen as Prog followed by the letter A B or C Set the first start time with the ON and OFF keys Press the key to move on to the ne...

Page 8: ...nts from 0 to 12 hours Each station must be assigned to a program Select the program with the ABC key Use the key to move to the next station Note If there is an overlap on the same station the 2nd st...

Page 9: ...connected to each other The control module must be equipped with a fully charged 9V Alkaline battery Ref 6LR61 2 PROGRAM REVIEW AND CHANGE 2 1 Plug the field transmitter optical connector onto the con...

Page 10: ...xample station 1 1 3 Repeatedly press the key until the desired station number appears 1 4 To start a station press the ON key Irrigation will start after 2 seconds after 10 seconds for Unik modules a...

Page 11: ...the ON or OFF mode The only way to change the mode is by carrying out a manual ON OFF It is impossible to change the mode by just pressing the key on the transmitter To return to the irrigation mode r...

Reviews: