The  ESP-TM  controller  is  factory-supplied  with  a  3-Volt 

lithium  coin  cell  backup  battery,  which  is  wrapped  in  a 

protective  insulator  strip  in  the  battery  drawer.  This  battery 

is  designed  to  maintain  program  information  for  several 

days  without  power.

If  electrical  power  to  the  ESP-TM  remains  uninterrupted, 

the  lithium  coin  cell  will  last  well  over  one  year.  However, 

long  or  frequent  power  interruptions  will  use  up  the  battery 

much  faster.

To  activate  this  battery,  remove  the  lower  face  panel  on  the

controller  and  remove  the  plastic  insulator  strip  from  the  battery.

Make  sure  battery  drawer  is  completely  closed,  then  reinstall

the  lower  face  panel.  See  page  25  for  complete  instructions.

Install  Battery

                                                                                                                                                                           

ESP-TM  Installation  and  Operation                                                                                                                                                                                           

Page  33

Install  Transformer

1

2

CAUTION:

DO  NOT

  plug  the  external  transformer  into

If  your  transformer  has  just  two  wires  go  to  step  2.

If  not,  connect  the  green  ground  wire  (which  is  the

longest  wire)  to  the  ground  screw  located  just  below

and  to  the  right  of  the  lower  wall  mounting  screw.

If  your  transformer  has  just  two  wires

then  a  ground  wire  is  not  necessary.

See  Note

Connect  one  pre-stripped  transformer  wire  to  each

of  the  flip  strip  terminals  labeled  24VAC.  Connect

either  wire  to  either  terminal;  polarity  of  these  wires

is  not  important.

into  an  electrical  outlet  until  all  other  connections  have

been  made.  In  addition,  connect  the  wires  from  the

transformer  to  the  ESP-TM  flip  strip  BEFORE  plugging

in  the  transformer.

ESP-TM  Installation  and  Operation               

Page  34

All manuals and user guides at all-guides.com

Summary of Contents for ESP-TM Series

Page 1: ...out Controls and Switches Turn Controller On and Off Adjust Water Budget Percent Use Manual Start Advance Run Test Program INSTALLING THE CONTROLLER Select Location Mount Controller Connect Field Wiri...

Page 2: ...ring a hot or cool period Start the sprinkler system manually Install a new battery Replace the fuse Troubleshoot a controller problem page 11 page 19 page 21 page 23 page 25 page 25 page 36 The contr...

Page 3: ...uttons used to set times and days and to make program changes A B Program Button used to select watering program A or B On some ESP models this button is labeled PGM Manual Start Advance Button used t...

Page 4: ...r system turns on and how long the sprinklers run Programming is the process of telling the controller exactly when and how long you want to water The controller opens and closes the remote control va...

Page 5: ...Program A You may have up to three separate start times for each program Enter the run time for each station assigned to Program A Enter 0 for stations that are not used in Program A Repeat steps 2 4...

Page 6: ...Program A Program B P N 632989A am pm am pm am pm am pm am pm am pm Select Watering Schedule To use a fixed schedule move the Schedule Slide Switch to one of the FIXED positions 2 every other day 3 ev...

Page 7: ...urrently set Press or to set the current minute 1 2 3 4 5 6 ESP TM Installation and Operation Page 11 Set Current Day Setting the current day varies somewhat depending on whether you are using a custo...

Page 8: ...Operation Page 13 Select Program The program that is currently selected appears in the far left corner of the display The display will show either PGM A or PGM B To select the program press the A B o...

Page 9: ...utton to set the selected day of the week on or off Turn the dial to the next day of the week Repeat steps 2 and 3 until you have set each day of the week either on or off ESP TM Installation and Oper...

Page 10: ...ird watering start times For example if you are growing new lawn seed you might want to water several times a day To do so you could set a program to run at 6 00 AM 11 00 AM and 4 00 PM 1 2 3 ESP TM I...

Page 11: ...hen the entire program is complete the display will change back to the current day and time If you forget to turn the dial to AUTO the controller will eventually set itself to automatic operation The...

Page 12: ...t the water budget to 120 that same station will run for 12 minutes 120 of 10 minutes The water budget feature can be useful for cutting back watering during cool winter months or for increasing water...

Page 13: ...TM Installation and Operation Page 23 Run Test Program The ESP TM controller has a built in test program that will run each station in sequence for two minutes You can use this program to check out t...

Page 14: ...s of programming data Rain Bird recommends that you replace the lithium coin cell battery once a year In addition if a short circuit occurs in the sprinkler system you may have to replace the fuse 1 2...

Page 15: ...pplied mounting template in the desired location on the wall Mark the screw center locations by punching through the template with a sharp tool Remove the template Two plastic spacers are provided for...

Page 16: ...res smaller than 18 gauge should be doubled over before being inserted into the flip strip To connect field wires raise the flip strip lever to the open position Insert the stripped wire into the roun...

Page 17: ...nal and COM terminal as shown in the illustration ESP TM Installation and Operation Page 31 Pump Start Relay Wiring NOTE Complete this section ONLY if your system requires a pump start relay The MV te...

Page 18: ...wer is completely closed then reinstall the lower face panel See page 25 for complete instructions Install Battery ESP TM Installation and Operation Page 33 Install Transformer 1 2 CAUTION DO NOT plug...

Page 19: ...g Use the MAN START ADV button to run a watering program Press MAN START ADV to cycle through each station If the fuse blows again on a particular station that station s solenoid or field wires may ha...

Page 20: ...t moving or advancing Same as Cause 3 See correction for Cause 3 SYMPTOM CAUSE CORRECTION Remove the lower face plate cover by gently prying it out along the slots on the outside right and left edges...

Reviews: