Station  Valve  Wiring

Connect  each  valve  by  its  own  separate  power  wire  to  one 

of  the  numbered  terminals  on  the  ESP-TM  flip  strip,  as 

shown  in  the  illustration.

Connect  a  common  wire  to  one  of  the  leads  on  each  valve. 

Connect  the  other  end  of  the  common  wire  to  the  COM 

terminal  on  the  flip  strip.  Wire  used  to  connect  the  valves 

must  be  code-approved  for  underground  installation.

Master  Valve  Wiring

NOTE:

  Complete  this  section 

ONLY

  if  your  system  requires 

a  master  valve  (an  automatic  valve  installed  on  the  mainline 

pipe  upstream  from  the  station  valves).

Connect  the  master  valve  wiring  to  the  MV  terminal  and 

COM  terminal  as  shown  in  the  illustration.

                                                                                                                                                                           

ESP-TM  Installation  and  Operation                                                                                                                                                                                           

Page  31

Pump  Start  Relay  Wiring

 

 

NOTE: 

  Complete  this  section 

ONLY

  if  your  system  requires

a  pump  start  relay.

The  MV  terminal  on  the  flip  strip  can  be  used  to  connect  a

pump  start  relay.  Connect  one  lead  of  the  24VAC  pump

start  relay  to  the  MV  terminal  and  the  other  lead  to  the

common  wire,  as  shown  in  the  illustration.

CAUTION:

  To  prevent  pump  damage  when  using  a  pump

start  relay,  use  a  jumper  to  connect  unused  stations  to  a

station  that  is  being  used.  If  program  information  is  lost

during  a  prolonged  power  outage,  the  ESP-TM  will  auto-

matically  run  a  "default"  program  when  power  is  restored.

This  program  runs  all  stations  for  10  minutes.  If  unused

stations  are  not  jumpered,  the  pump  will  operate  with  no

flow  (dead-head)  during  this  10-minute  period.  Dead-

heading  may  cause  the  pump  to  overheat  or  burn  out.

ESP-TM  Installation  and  Operation               

Page  32

All manuals and user guides at all-guides.com

Summary of Contents for ESP-TM Series

Page 1: ...out Controls and Switches Turn Controller On and Off Adjust Water Budget Percent Use Manual Start Advance Run Test Program INSTALLING THE CONTROLLER Select Location Mount Controller Connect Field Wiri...

Page 2: ...ring a hot or cool period Start the sprinkler system manually Install a new battery Replace the fuse Troubleshoot a controller problem page 11 page 19 page 21 page 23 page 25 page 25 page 36 The contr...

Page 3: ...uttons used to set times and days and to make program changes A B Program Button used to select watering program A or B On some ESP models this button is labeled PGM Manual Start Advance Button used t...

Page 4: ...r system turns on and how long the sprinklers run Programming is the process of telling the controller exactly when and how long you want to water The controller opens and closes the remote control va...

Page 5: ...Program A You may have up to three separate start times for each program Enter the run time for each station assigned to Program A Enter 0 for stations that are not used in Program A Repeat steps 2 4...

Page 6: ...Program A Program B P N 632989A am pm am pm am pm am pm am pm am pm Select Watering Schedule To use a fixed schedule move the Schedule Slide Switch to one of the FIXED positions 2 every other day 3 ev...

Page 7: ...urrently set Press or to set the current minute 1 2 3 4 5 6 ESP TM Installation and Operation Page 11 Set Current Day Setting the current day varies somewhat depending on whether you are using a custo...

Page 8: ...Operation Page 13 Select Program The program that is currently selected appears in the far left corner of the display The display will show either PGM A or PGM B To select the program press the A B o...

Page 9: ...utton to set the selected day of the week on or off Turn the dial to the next day of the week Repeat steps 2 and 3 until you have set each day of the week either on or off ESP TM Installation and Oper...

Page 10: ...ird watering start times For example if you are growing new lawn seed you might want to water several times a day To do so you could set a program to run at 6 00 AM 11 00 AM and 4 00 PM 1 2 3 ESP TM I...

Page 11: ...hen the entire program is complete the display will change back to the current day and time If you forget to turn the dial to AUTO the controller will eventually set itself to automatic operation The...

Page 12: ...t the water budget to 120 that same station will run for 12 minutes 120 of 10 minutes The water budget feature can be useful for cutting back watering during cool winter months or for increasing water...

Page 13: ...TM Installation and Operation Page 23 Run Test Program The ESP TM controller has a built in test program that will run each station in sequence for two minutes You can use this program to check out t...

Page 14: ...s of programming data Rain Bird recommends that you replace the lithium coin cell battery once a year In addition if a short circuit occurs in the sprinkler system you may have to replace the fuse 1 2...

Page 15: ...pplied mounting template in the desired location on the wall Mark the screw center locations by punching through the template with a sharp tool Remove the template Two plastic spacers are provided for...

Page 16: ...res smaller than 18 gauge should be doubled over before being inserted into the flip strip To connect field wires raise the flip strip lever to the open position Insert the stripped wire into the roun...

Page 17: ...nal and COM terminal as shown in the illustration ESP TM Installation and Operation Page 31 Pump Start Relay Wiring NOTE Complete this section ONLY if your system requires a pump start relay The MV te...

Page 18: ...wer is completely closed then reinstall the lower face panel See page 25 for complete instructions Install Battery ESP TM Installation and Operation Page 33 Install Transformer 1 2 CAUTION DO NOT plug...

Page 19: ...g Use the MAN START ADV button to run a watering program Press MAN START ADV to cycle through each station If the fuse blows again on a particular station that station s solenoid or field wires may ha...

Page 20: ...t moving or advancing Same as Cause 3 See correction for Cause 3 SYMPTOM CAUSE CORRECTION Remove the lower face plate cover by gently prying it out along the slots on the outside right and left edges...

Reviews: