ESP-TM  controllers  are  designed  for  indoor  mounting

only.  For  best  results,  mount  the  controller  at  eye  level.

Mount  the  controller  so  that  a  117-Volt  AC  power  outlet

is  within  five  feet  of  the  controller  so  the  wires  from  the

external  transformer  can  be  easily  connected  to  the

controller.

Select  Location

INSTALLING  THE  CONTROLLER

The  ESP-TM  controller  has  three  "keyhole"  slots  on

the  back  of  the  cabinet.  Use  these  slots  to  mount  the

controller  to  a  flat  wall  or  vertical  stud.  Always  use

lower  mounting  hole  "D"  to  secure  the  bottom  of  the

controller.

                                                                                                                                                                           

ESP-TM  Installation  and  Operation                                                                                                                                                                                           

Page  27

Mount  Controller

1

2

Place  the  supplied  mounting  template  in  the  desired 

location  on  the  wall.  Mark  the  screw  center  locations  by 

punching  through  the  template  with  a  sharp  tool.

Remove  the  template.  Two  plastic  spacers  are  provided 

for  the  upper  mounting  screws  only.  (See  illustration  on 

the  next  page.)

Slip  the  spacers  over  the  screws  and  drive  them  into  the 

wall  or  stud  at  the  upper  keyhole  marks:  holes  A  and  C 

for  flat  surfaces,  or  hole  B  only  for  an  exposed  stud.

When  the  wide,  flat  end  of  the  spacer  is  pressed  against 

the  wall  or  stud,  the  screw  is  at  the  proper  depth.  Do 

NOT 

drive  a  fastener  into  location  D  at  this  time.

Remove  the  controller's  lower  face  panel  by  gently  prying 

out  the  panel  at  the  slots  on  the  left  and  right  sides.

Hang  the  controller  on  the  upper  keyhole  slots.

 

Make 

 

sure

the  spacers  are  in  the  upper,  narrow  portion  of  the  slots.

Then  drive  a  fastener  through  lower  mounting  hole  D.  The

controller  should

 

now  be  secure.

3

4

ESP-TM  Installation  and  Operation               

Page  28

All manuals and user guides at all-guides.com

Summary of Contents for ESP-TM Series

Page 1: ...out Controls and Switches Turn Controller On and Off Adjust Water Budget Percent Use Manual Start Advance Run Test Program INSTALLING THE CONTROLLER Select Location Mount Controller Connect Field Wiri...

Page 2: ...ring a hot or cool period Start the sprinkler system manually Install a new battery Replace the fuse Troubleshoot a controller problem page 11 page 19 page 21 page 23 page 25 page 25 page 36 The contr...

Page 3: ...uttons used to set times and days and to make program changes A B Program Button used to select watering program A or B On some ESP models this button is labeled PGM Manual Start Advance Button used t...

Page 4: ...r system turns on and how long the sprinklers run Programming is the process of telling the controller exactly when and how long you want to water The controller opens and closes the remote control va...

Page 5: ...Program A You may have up to three separate start times for each program Enter the run time for each station assigned to Program A Enter 0 for stations that are not used in Program A Repeat steps 2 4...

Page 6: ...Program A Program B P N 632989A am pm am pm am pm am pm am pm am pm Select Watering Schedule To use a fixed schedule move the Schedule Slide Switch to one of the FIXED positions 2 every other day 3 ev...

Page 7: ...urrently set Press or to set the current minute 1 2 3 4 5 6 ESP TM Installation and Operation Page 11 Set Current Day Setting the current day varies somewhat depending on whether you are using a custo...

Page 8: ...Operation Page 13 Select Program The program that is currently selected appears in the far left corner of the display The display will show either PGM A or PGM B To select the program press the A B o...

Page 9: ...utton to set the selected day of the week on or off Turn the dial to the next day of the week Repeat steps 2 and 3 until you have set each day of the week either on or off ESP TM Installation and Oper...

Page 10: ...ird watering start times For example if you are growing new lawn seed you might want to water several times a day To do so you could set a program to run at 6 00 AM 11 00 AM and 4 00 PM 1 2 3 ESP TM I...

Page 11: ...hen the entire program is complete the display will change back to the current day and time If you forget to turn the dial to AUTO the controller will eventually set itself to automatic operation The...

Page 12: ...t the water budget to 120 that same station will run for 12 minutes 120 of 10 minutes The water budget feature can be useful for cutting back watering during cool winter months or for increasing water...

Page 13: ...TM Installation and Operation Page 23 Run Test Program The ESP TM controller has a built in test program that will run each station in sequence for two minutes You can use this program to check out t...

Page 14: ...s of programming data Rain Bird recommends that you replace the lithium coin cell battery once a year In addition if a short circuit occurs in the sprinkler system you may have to replace the fuse 1 2...

Page 15: ...pplied mounting template in the desired location on the wall Mark the screw center locations by punching through the template with a sharp tool Remove the template Two plastic spacers are provided for...

Page 16: ...res smaller than 18 gauge should be doubled over before being inserted into the flip strip To connect field wires raise the flip strip lever to the open position Insert the stripped wire into the roun...

Page 17: ...nal and COM terminal as shown in the illustration ESP TM Installation and Operation Page 31 Pump Start Relay Wiring NOTE Complete this section ONLY if your system requires a pump start relay The MV te...

Page 18: ...wer is completely closed then reinstall the lower face panel See page 25 for complete instructions Install Battery ESP TM Installation and Operation Page 33 Install Transformer 1 2 CAUTION DO NOT plug...

Page 19: ...g Use the MAN START ADV button to run a watering program Press MAN START ADV to cycle through each station If the fuse blows again on a particular station that station s solenoid or field wires may ha...

Page 20: ...t moving or advancing Same as Cause 3 See correction for Cause 3 SYMPTOM CAUSE CORRECTION Remove the lower face plate cover by gently prying it out along the slots on the outside right and left edges...

Reviews: