::= { radSNMP_Mod_Status 1 }
radMinorAlarmStatus OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS current
DESCRIPTION
"Minor Alarm status:
A bit field. 0 = PASS, 1 = FAIL
Bit 1 = Terrestrial clock activity detect
Bit 2 = Tx data activity detect
Bit 3 = Interleaver FIFO empty error
Bit 5 = Loss of frame synchronization
"
::= { radSNMP_Mod_Status 2 }
radCommonAlarmStatus OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS current
DESCRIPTION
"Common Alarm status:
A bit field. 0 = PASS, 1 = FAIL
Bit 0 = -12V alarm.
Bit 1 = +12V alarm.
Bit 2 = +5V alarm.
"
::= { radSNMP_Mod_Status 3 }
radLatchedMajorAlarmStatus OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS current
DESCRIPTION
"Major Alarm latched status:
A bit field. 0 = PASS, 1 = FAIL
Bit 1 = Oversample Clock PLL Lock
Bit 2 = FPGA Configuration Error
Bit 3 = Synthesis Clock PLL Lock
Bit 4 = External Reference PLL Lock
"
::= { radSNMP_Mod_Status 4 }
radLatchedMinorAlarmStatus OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS current
DESCRIPTION
"Minor Alarm latched status:
A bit field. 0 = PASS, 1 = FAIL
Bit 1 = Terrestrial clock activity detect
Bit 2 = Tx data activity detect
Bit 3 = Interleaver FIFO empty error
Bit 5 = Loss of frame synchronization
"
::= { radSNMP_Mod_Status 5 }
radLatchedCommonAlarmStatus OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS current
Summary of Contents for RCS20
Page 2: ......
Page 36: ...Installation RCS20 M N Redundancy Switch 2 24 TM056 Rev 2 3...
Page 47: ...RCS20 M N Redundancy Switch User Interfaces TM056 Rev 2 3 4 9 Figure 4 2...
Page 48: ...User Interfaces RCS20 M N Redundancy Switch 4 10 TM056 Rev 2 3 Figure 4 3...
Page 49: ...RCS20 M N Redundancy Switch User Interfaces TM056 Rev 2 3 4 11 Figure 4 4...
Page 58: ...User Interfaces RCS20 M N Redundancy Switch 4 20 TM056 Rev 2 3...
Page 84: ...Maintenance RCS20 M N Redundancy Switch 6 6 TM056 Rev 2 3...
Page 100: ...Appendix A RCS20 M N Redundancy Switch A 14 TM056 Rev 2 3...
Page 112: ...Appendix B RCS20 M N Redundancy Switch B 12 TM056 Rev 2 3...