TM056 – Rev. 2.3
radDifferentialEncoder OBJECT-TYPE
SYNTAX INTEGER {
off(0)
}
ACCESS read-write
STATUS optional
DESCRIPTION
"Disables differential encoder
unsupported
"
::= { radSNMP_Mod_NV_Status 23 }
radAlarmMaskEnable OBJECT-TYPE
SYNTAX INTEGER {
disable(0),
enable(1)
}
ACCESS read-write
STATUS optional
DESCRIPTION
"unsupported"
::= { radSNMP_Mod_NV_Status 24 }
radMajorAlarmMask OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS current
DESCRIPTION
"Major Alarm mask:
Bit 1 = Oversample Clock PLL Lock
Bit 2 = FPGA Configuration Error
Bit 3 = Synthesis Clock PLL Lock
Bit 4 = External Reference PLL Lock
"
::= { radSNMP_Mod_NV_Status 25 }
radMinorAlarmMask OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS current
DESCRIPTION
"Minor Alarm mask:
Bit 1 = Terrestrial clock activity detect
Bit 2 = Tx data activity detect
Bit 3 = Interleaver FIFO empty error
Bit 5 = Loss of frame synchronization
"
::= { radSNMP_Mod_NV_Status 26 }
radCommonAlarmMask OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS current
DESCRIPTION
"Common Alarm mask:
Bit 0 = -12V alarm.
Bit 1 = +12V alarm.
Bit 2 = +5V alarm.
"
::= { radSNMP_Mod_NV_Status 27 }
Summary of Contents for RCS20
Page 2: ......
Page 36: ...Installation RCS20 M N Redundancy Switch 2 24 TM056 Rev 2 3...
Page 47: ...RCS20 M N Redundancy Switch User Interfaces TM056 Rev 2 3 4 9 Figure 4 2...
Page 48: ...User Interfaces RCS20 M N Redundancy Switch 4 10 TM056 Rev 2 3 Figure 4 3...
Page 49: ...RCS20 M N Redundancy Switch User Interfaces TM056 Rev 2 3 4 11 Figure 4 4...
Page 58: ...User Interfaces RCS20 M N Redundancy Switch 4 20 TM056 Rev 2 3...
Page 84: ...Maintenance RCS20 M N Redundancy Switch 6 6 TM056 Rev 2 3...
Page 100: ...Appendix A RCS20 M N Redundancy Switch A 14 TM056 Rev 2 3...
Page 112: ...Appendix B RCS20 M N Redundancy Switch B 12 TM056 Rev 2 3...