18.6. Starting test control 
 
After all the necessary codes are entered following information are  
displayed in the main window workspace: 

 

 Operator 

name, 

  Product code and name, 

  Product nominal mass (Qn), 

  Tare ascribed to the product (for controls with average tare), 

 Batch 

quantity, 

 Test 

control 

mode. 

 
 

Exemplary look of workspace in the main window: 
 

 

 
 

Depending on settings in the computer program (for a selected product), 
operators can perform testing: 

 

  With average tare, 

  full / empty (destructive), 

  empty / full, 

  full / empty. 

 

Press 

 to start testing. 

 
 
 

18.7. Test control with average tare 
 
Procedure: 

 

  After starting a test control following data are displayed in the display 

workspace: 

 

44

Summary of Contents for Y/KTPS Series

Page 1: ...Packaged Goods Network version WLY KTPS Scales WPY KTPS Scales MA NU FACTU R ER OF ELEC TRON IC WEIGHING INSTRUMENTS RADWAG Wagi Elektroniczne 26 600 Radom Bracka 28 Street POLAND Phone 48 48 38 48 8...

Page 2: ...2 JANUARY 2011...

Page 3: ...2 K 8 2 Screen function buttons 12 9 INDICATING WINDOW 13 10 PROGRAM STRUCTURE 14 10 1 Inventory of parameters 15 10 1 1 Scale parameters weighing 15 10 1 2 Communication 15 10 1 3 Devices 16 10 1 4 D...

Page 4: ...H PROGRAM KTP NET 38 18 1 ith computers 38 Connection w 18 2 Choosing product 39 18 2 1 Choosing products by entering identifier 40 18 2 2 Product name related searching 40 18 2 3 Product code related...

Page 5: ...ds and operators product code operator code batch quantity batch number Start Stop test control Defining product codes with descriptions names on the computer level Users can add individual names that...

Page 6: ...failures caused by inappropriate maintenance of the device or failures of thermal or chemical origin or caused by atmospheric discharge overvoltage in mains or other random event Inappropriate cleanin...

Page 7: ...feet Levelling is correct if air bubble is situated in the central position 4 2 WPY KTPS D2 scales A Take the device out of the package B Put the scale on an even stiff ground C Fit the pan and the br...

Page 8: ...hould be levelled by turning regulation feet Levelling is correct if air bubble is situated in the central position 5 SCALE CONSTRUCTION 5 1 Main dimensions 5 1 1 WPY KTPS C1 scales 5 1 2 WPY KTPS D2...

Page 9: ...f connectors 5 2 1 Connectors description in PUE 7 1 Ethernet RJ45 2 RS232 COM1 3 USB 1 power supply socket 2 I O RS232 COM2 5 2 2 Connectors description in PUE 7P 1 Ethernet RJ45 2 RS232 COM1 3 USB 1...

Page 10: ...latforms 3 4 5 2 4 Connector with RS232 and I O RS232 DB9 M male top view Pin2 RxD Pin3 TxD Pin5 GND I O RS232 DSUB15 F female top view Pin1 GNDWE Pin2 OUT1 Pin3 OUT2 Pin4 COMM Pin5 6 9VDC Pin6 IN4 Pi...

Page 11: ...AD diode starts to light Press to start the operating system loading procedure Windows CE together with RADWAG software loading is signalled by blinking the red diode ON LOAD When the loading procedur...

Page 12: ...active after establishing a connection with the computer Selecting products Selecting operators Batch quantity declaration 8 2 Screen function buttons Key Description Batch number declaration Startin...

Page 13: ...9 INDICATING WINDOW In the main application window one can see four separate parts 1 The working mode information is displayed in the top part of the display It is accompanied by date and time Additio...

Page 14: ...are KTP NET 2003 can be found in ch 18 of this manual 4 There are screen buttons below the workspace description of button functions see ch 8 2 of this manual 10 PROGRAM STRUCTURE The main menu has be...

Page 15: ...n Description Value Platform 1 Median Filter 0 5 Filter Fast Autozero Yes LO threshold 0 Weighing software version 2 0 10 1 2 Communication Icon Description Value COM1 Baud Rate 9600 Data bits 8 Stop...

Page 16: ...P No IP Address 192 168 0 2 Subnet mask 255 255 255 0 Gateway 192 168 0 1 Tcp Port 4001 10 1 3 Devices Icon Description Value Computer Port None Address 1 Printer Port COM1 Code page 1250 Barcode read...

Page 17: ...splay Icon Description Value Actions Left proximity sensor None Right proximity sensor None Input 1 None Input 2 None Input 3 None Input 4 None Set Default Show all platforms No 10 1 5 Others Icon Des...

Page 18: ...for non verified scale Icon Description Value Platform 1 Setting of start mass Calibration 10 2 Navigating within the menu Owing to the colour display with the touch panel navigating within the menu i...

Page 19: ...diting field Screen keyboard on off One level up 10 2 2 Return to weighing The changes introduced are saved for good after they are confirmed Press several times until the following message box appear...

Page 20: ...rder to assure a long term operating period with appropriate measurements following principles should be adhered to Avoid applying mechanical shocks to the weight pan Loads should be placed in the cen...

Page 21: ...hoose a platform on the touch panel if necessary put a package on the pan and press You will see the indication equal zero and following symbols usually appear Net and After placing a load on the weig...

Page 22: ...oth in the switching point the autozero zone While in AUTOZERO pictogram appears Then pictogram is off and a scale returns to weighing in the I range 12 SCALE PARAMETERS Users can set the scale accord...

Page 23: ...anual select Median Filter and then set an appropriate value Accessible settings None median filter is off 0 5 1 1 5 2 2 5 filtering level to choose 12 2 Filter This filter is intended to suppress con...

Page 24: ...ected automatically However in particular cases this function can disrupt the measurement process e g slow pouring of liquid or powder on the weighing pan In this case it is advisable to disable the a...

Page 25: ...ation 13 1 RS 232 settings Procedure Enter Communication according to ch 13 of the manual select COM1 or COM2 and then set an appropriate value For RS 232 following parameters are accessible Baud Rate...

Page 26: ...two computers It operates in mode client server Server awaits on connection initiation on a specified port while client initiates connection to the server Scale software allows setting the port for t...

Page 27: ...COM1 RS 232 COM2 Tcp 14 1 2 Computer address Procedure Enter Devices parameter group as described in chapter 14 of the manual Choose Computer Address then the window Address with the screen keyboard a...

Page 28: ...displayed Write the required code page and confirm by pressing Notice The default value is 1250 code page for Middle East Europe 14 3 Barcode scanner Cooperating with a barcode scanner allows immediat...

Page 29: ...et the appropriate value Barcode scanners can be connected to RS 232 COM1 RS 232 COM2 14 3 2 Offset It outlines the first character that is significant for searching the assortment database All preced...

Page 30: ...erformed by Typing a password on a keyboard Approaching a transponder card to the reader The card needs to be registered first Notice In case of problems with reading transponder cards check the subme...

Page 31: ...nput has been attributed a function it has been activated at the same time If a sensor or input has no ascribed a function in stays inactive Procedure Press and then Display Actions Ascribe actions fo...

Page 32: ...terminal is equipped with two platforms users can switch between platforms in two ways By pressing the platform number on the scale screen By activating in parameters all platforms that will be separa...

Page 33: ...rs which influence the operation of the scale They are gathered in group Others e g language beep etc To enter Others press and then Others 16 1 Languages Procedure Enter submenu Others according to c...

Page 34: ...abled Sensors Sound for proximity sensors enabled All Sound for buttons and proximity sensors enabled 16 4 Touch panel calibration Touch panel calibration is required when inappropriate operation is r...

Page 35: ...ale Scales require to recalculate internal divisions to more suitable ones e g g kg etc In order to do this they require a calibration factor It is adjusted during the calibration procedure using a ma...

Page 36: ...following message box appears Put calibration mass on pan of platform 1 and then select After the procedure of calibration factor determination following command appears Return to weighing saving para...

Page 37: ...t mass adjustment It is possible to adjust only a start mass it helps to correct the start zero when the span does not change Procedure Enter submenu Customer Calibration according to ch 17 and select...

Page 38: ...nection with computers In order to establish connection with computer software KTP NET In submenu Computer choose the communication port and scale address see ch 14 1 of this manual In submenu Communi...

Page 39: ...last fourth line of the work area there are descriptions of button functions Using and this line can be moved on the screen In order to start the test control choose Product Operator Batch quantity B...

Page 40: ...2 2 Product name related searching Procedure Press button then the list of products from the database is displayed Using buttons or set marker next to required product When the number of records in t...

Page 41: ...set marker next to the required product When the number of records in the database is significant users can search the database See ch 18 2 2 In order to confirm the selected item press Press to leave...

Page 42: ...er operator identifier 18 3 2 Wyb r z listy po nazwie operatora Procedure Press button then the list of users from the database is displayed Using or set marker next to required operator When the numb...

Page 43: ...can be enabled form the level of program KTP NET If all this conditions are fulfilled approaching the registered card to the card reader causes automatic logging in of the operator 18 4 Entering batc...

Page 44: ...controls with average tare Batch quantity Test control mode Exemplary look of workspace in the main window Depending on settings in the computer program for a selected product operators can perform t...

Page 45: ...atus F5 End Description of button terminating control NET Net mass of tested products According to the command on the screen put on the weight pan subsequent products and after stabilizing press to se...

Page 46: ...sults OK positive WRONG negative Test in progress Status F5 End Description of button terminating control NET Net mass of tested products According to the command on the screen put on the weight pan s...

Page 47: ...creen put on the weight pan subsequent full or empty packages and after stabilizing press After completing a test control different data are displayed in the workspace see ch 18 7 18 10 Estimating ave...

Page 48: ...ages sample of at least 10 measurements cannot exceed 0 25 of the maximum acceptable negative limit T with reference to the nominal package weight According to the command ordering what to put on the...

Page 49: ...Ethernet 4In 4Out Net Gross weight 2 7 3 6kg Package dimensions 490 x 300 x 150mm WLY 6 12 KTPS C1 R WLY 12 30 KTPS C1 R WLY 60 KTPS C2 R WLY 60 120 KTPS C2 R Scale type WLY 6 12 KTPS C1 K WLY 12 30 K...

Page 50: ...t 2 7 3 6kg Package dimensions 490 x 300 x 150mm WPY 3 6 KTPS C1 K WPY 6 15 KTPS C1 K WPY 15 30 KTPS C1 K WPY 30 60 KTPS C1 K Scale type WPY 3 6 KTPS C1 R WPY 6 15 KTPS C1 R WPY 15 30 KTPS C1 R WPY 30...

Page 51: ...beyond the tare range Err8 Tarring zeroing operation time exceeded NULL Zero value from the AD converter FULL Measurement range overflow HI Display range overflow LH Start mass error the mass on the w...

Page 52: ...systems can omit unnecessary information by using parameters that mark the beginning and the length of the code required to analyse 5 A special protocol is required in order the code be received by RA...

Page 53: ...L E C T R O N I C W E I G H I N G I N S T R U M E N T S RADWAG WAGI ELEKTRONICZNE 26 600 Radom Bracka 28 Street POLAND Phone 48 48 38 48 800 phone fax 48 48 385 00 10 Selling Department 48 48 366 80 0...

Reviews: