67
24.1. Home Screen
24.2. Local Settings
In order to access local settings, press operation panel key to which
<
Working mode parameters>
pictogram is assigned:
Procedure:
•
Enter
<
/ Working modes / Dosing>
submenu.
•
Select
<Dosing mode>
parameter and set one of the dosing modes:
Manual dosing
Manual dosing with MIN, MAX thresholds.
Automatic dosing
Automatic 1-, 2-stage dosing with automated activation of dosing outputs.
•
List of available dosing functions changes depending on the selected
dosing mode.
List of automatic dosing functions
Fast dosing threshold [DT1]
Enter to set mass value for rough dosing in case of automatic
2-stage dispensing.
Dosing threshold [DT2]
Enter to set target mass value to be dosed in case of an
automatic dispensing.
Fast dosing output
Enter to declare outputs for rough dosing in case of automatic
2-stage dispensing.
Dosing outputs
Enter to declare outputs for precise dosing in case
of automatic 2-stage dispensing.
Chute outputs
Enter to activate chute; signalling informing that the silos
is being emptied switches on.
Permission to start
Enter to send signal triggering process START.