Figure 5-3
H.323 protocol section of the Protocols tab
Step 4
Select H.323 to enable the MCU to operate with the H.323 protocol.
Step 5
Enter the gatekeeper's FQDN or IP address and port number.
The default port is 1719.
Step 6
Select Apply.
Step 7
Login to the MCU Administrator web interface.
Step 8
Locate the Status Map section.
Figure 5-4
The Status Map showing the gatekeeper connection
Step 9
Verify the MCU is connected to the Ethernet.
Step 10
Verify the MCU is connected to the Gatekeeper.
Configuring SIP Server Settings
You can configure settings for SIP server profiles which set how the MCU and the registrar
interact.
Depending on connection types supported by the SIP server, MCU supports these transport
connection types for sending messages to SIP server:
•
UDP
•
TCP
•
TLS
Procedure
Step 1
Select Configuration
.
Step 2
Select Protocols.
RADVISION | Installation Guide for Scopia Elite 6000 Series MCU Version 8.0
Performing the MCU Initial Configuration | 34