Assign an IP Address to the MVP 13
C
ONNECT
TO
A
PC
You make the serial connection by connecting a PC terminal
equipped with a terminal emulation application to the front panel
serial port of the MVP.
Procedure
1.
Connect the MVP COM port on the front panel to a
PC terminal serial port using the supplied terminal
cable.
2.
Run a terminal emulation application (such as
HyperTerminal) on the PC.
3.
Configure the PC communication settings for the
serial port as follows:
9600 Baud rate
8 data bits
1 stop bit
No parity
No flow control
4.
Start the terminal emulation application on the PC.
5.
Turn on or reset the MVP.
Note
The debug mode prompt appears before the boot
Configuration prompt. Ignore this message and wait for
the boot Configuration prompt to appear.
6.
Press any key at the command prompt to display
the network configuration
Main
menu.