background image

 Configure the MCU 11

C

HANGE

 

THE

 

D

EFAULT

 

A

DMINISTRATOR

 

P

ASSWORD

The default password of the MCU is set to null. It is recommended 
that you change the default administrator password. 

 

Procedure

1.

In the sidebar, click the 

Device

 button to display 

the 

Device

 configuration tabs.

2.

In the 

Users

 tab select the Administrator user 

profile and click 

Edit

.

The 

Edit User

 dialog box displays where you can reset 

the administrator password.
The new password is valid the next time you sign in to 
the MCU after signing out from the current session. 

C

HECK

 MCU 

S

ERVICE

 P

REFIXES

The MCU includes pre-configured default service prefixes which 
are combined with a unique number to create the conference ID 
which you dial to join or create a conference. The default settings 
are listed in the 

Services

 tab of the MCU interface. You can 

modify the existing prefixes to suit your network dialing plan or 
define new services and add them to the list. 
You must ensure that the service prefix numbers are not identical 
to the first digits of any of your network endpoint phone numbers 
or aliases. 

 

Procedure

1.

In the MCU 

Services

 tab, click 

Add

 to add a new 

service, or select a service and click 

Edit

 to modify 

that service.

2.

Type the prefix number for this service and set or 
modify additional settings as required and click 

OK

.

After confirming your settings, the MCU is automatically 
updated with the new service profile settings. 

Summary of Contents for SCOPIA 100 MCU

Page 1: ...Multipoint Conferencing Unit SCOPIA100 MCU Quick Start Version 5 7...

Page 2: ...VISION Ltd reserves the right to revise this publication and make changes without obligation to notify any person of such revisions or changes RADVISION Ltd may make improvements or changes in the pro...

Page 3: ...k and Verify the Equipment 3 Prepare a Checklist 4 Prepare the Site 5 Mount the SCOPIA100 MCU Unit in a 19 Rack Optional Setting Up the MCU Component 6 Assign an IP Address to the MCU 7 Connect to the...

Page 4: ...responsible for signaling and audio The MVP the lower component is responsible for video The MCU and MVP components connect via the Ethernet For correct operation the MVP card must register with the...

Page 5: ...LED on the SCOPIA MCU MC LED on the MVP Lights green when the MCU MVP is registered with a gatekeeper or when there is no gatekeeper registered and the auto attendant feature is enabled LOAD LED Light...

Page 6: ..._ _ _ _ _ _ _ _ _ _ _ _ MVP IP subnet mask _ _ _ _ _ _ _ _ _ _ _ _ Router IP address _ _ _ _ _ _ _ _ _ _ _ _ Note Typically the MVP subnet mask and router IP address are the same as those used for the...

Page 7: ...0 MCU unit right side up on a hard flat surface with the front panel facing you 3 Position a mounting bracket over the mounting holes on each side of the SCOPIA100 MCU unit Figure 2 Fitting a Bracket...

Page 8: ...serial port configuration of the MCU only at startup during a short period indicated by a 6 second countdown Once the initialization phase is complete the only way you can access the configuration men...

Page 9: ...ppear 6 Press any key at the command prompt to display the network configuration Main menu Figure 3 Network Configuration Main Menu Warning Configuration of any of the parameters other than N should n...

Page 10: ...Network Port Values 2 Type the IP address default router IP address and IP subnet mask pressing Enter to proceed from one parameter to the next 3 Press Q to finalize the new settings and return to the...

Page 11: ...e and password in the Name and Password fields and click Go Note The default name is admin and the password is null It is recommended that you change these settings for security reasons For more infor...

Page 12: ...port number of the network gatekeeper on which H 323 calls to the MCU are routed and click Next The SIP Settings window displays 4 Type the SIP proxy IP port and default domain address through which S...

Page 13: ...service prefixes which are combined with a unique number to create the conference ID which you dial to join or create a conference The default settings are listed in the Services tab of the MCU interf...

Page 14: ...4 Click Save ASSIGN AN IP ADDRESS TO THE MVP The first time you install the MVP you assign an IP address using a terminal cable connection to access the boot configuration menu At power up the MVP go...

Page 15: ...2 Run a terminal emulation application such as HyperTerminal on the PC 3 Configure the PC communication settings for the serial port as follows 9600 Baud rate 8 data bits 1 stop bit No parity No flow...

Page 16: ...t network properties screen displays Figure 6 Default Network Properties Screen Press any key to start configuration Main menu N Configure default network port values P Change the configuration softwa...

Page 17: ...s Enter to proceed to the next setting otherwise just press Enter to proceed to the next setting 5 Press any key to return to the main MVP configuration menu CHANGE THE CONFIGURATION SOFTWARE PASSWORD...

Page 18: ...MCU IP address and press any key to return to the main MVP configuration menu Ensure that you use the same IP address as the one you configured at Configure the MCU IP Address on page 8 SAVE MVP NETWO...

Page 19: ...conference or to invite others into the conference REQUIREMENTS The following information is necessary for dialing into and monitoring a conference A conference ID number composed of a valid service...

Page 20: ...he conference ID number for dialing directly into the conference Procedure 1 Compose a conference ID number using an appropriate service prefix and a unique ID number up to 256 characters long 2 Notif...

Reviews: