28
Installation
– Installation type
3.9.5
In this submenu you can choose the type of the installation,
Heating, Cooling or reversible.
1
st
Page
2
nd
page
Important note!!!
These modifications will be only available if the Heating / Cooling
information is done by the main zone programmer. Check the
position of the “HC” parameter on the MASTER-RF of the
installation.
(Check the leaflet of the MASTER-RF for more explanation)
Heating:
To be used when your house is only equipped with heating system
only.
Cooling:
To be used when your house is only equipped with cooling system
only.
Reversible Manu:
To be used when your house is only equipped with heating and
cooling systems.
A new “
Heat & Cool
”
button will be created in the main menu.
See the
part “
Heat & Cool
” for more information.
Reversible Auto:
To be used when your house is only equipped with heating and
cooling systems.
Generally used when automatic reversible heat pumps is installed.
The working mode heating or cooling will be done by the “
H&C
Module
”.
In this case the Heating or cooling information will be done by an
external sensor or a contact connected on a special input on the
H&C Module
.
(Check the leaflet of the H&C Module for more explanation)