Chapter 4: BIOS configuration
43
Console Redirection sub-menu
Options in this menu configure console redirection.
Figure 4-9. Console Redirection sub-menu
Main
F1
Help
↑↓
Select Item
–/+
Change Values
F9
Setup Defaults
ESC
Exit
←→
Select Menu
Enter Select Sub-Menu F10 Save and Exit
PhoenixBIOS Setup Utility
<Tab>, <Shift-Tab>, or <Enter>
selects field.
Item Specific Help
Com Port Address
[On-board COM
A]
Baud Rate
[115.2K]
Console Type
[VT100]
Flow Control
[None]
Console connection:
[Direct]
Continue C.R. after POST:[On]
Console Redirection
Advanced
Field
Description
Com Port Address
Specifies the serial port to use for console redirection. You
can select one of these:
•
On-board COM A (default)
: The system uses COM A
for rediretion.
•
Disabled
: The system does not redirect input.
Baud Rate
Specifies the baud rate at which the COM port operates.
You can select one of these:
• 600
• 9600
• 1200
• 19.2K
• 2400
• 38.4K
• 4800
• 115.2K (default)
Console Type
Identifies the console type. You can select one of these:
• VT100 (default)
• PC ANSI
Flow Control
Specifies flow control. You can select one of these:
• None (default)
• CTS/RTS
• XON/XOFF
Summary of Contents for EPS-6315
Page 1: ...007 01361 0005 April 2005 www radisys com EPC 6315 Hardware Reference ...
Page 6: ...EPC 6315 Hardware Reference vi ...
Page 16: ...EPC 6315 Hardware Reference 6 ...
Page 32: ...EPC 6315 Hardware Reference 22 ...
Page 60: ...EPC 6315 Hardware Reference 50 ...
Page 76: ...EPC 6315 Hardware Reference 66 ...
Page 88: ...EPC 6315 Hardware Reference 78 ...
Page 90: ...EPC 6315 Hardware Reference 80 ...