D9000/D7000 Series Operation & Installation Manual
Page 41
74-07692-000-C 4/97
D9210B Access Control Module
The Radionics D9210B Access Control Interface
is a 4-wire powered device providing
connections for an access door point and door
strike. The D9412 can supervise eight Access
Control Modules, and the D7412 can supervise
two Access Control Modules. Each Access
Control Module supports one door to control
access. Programming allows each access door
to be configured independently.
Using Weigand-style cards or tokens, the
D9210B can allow access for up to 996 cards/
tokens on the D9412, 396 on the D7412. User
access authority can be configured to restrict
access to certain doors or to certain periods of
time. The reading of access cards, in addition to
granting access, can control whether the system
will disarm. Used with the D9412, the D9210B
recognizes 250 master users by user name,
passcode, and access authority. The D9210B
recognizes 99 master users when used with the
D7412. Each master user will support three
subusers with unique cards/tokens having the
same access level as the master user.
♦
Door
Module
1
2
3
4
5
6
1
ON
ON
ON
*
ON
ON
2
OFF
ON
ON
*
ON
ON
3
ON
OFF
ON
*
ON
On
4
OFF
OFF
ON
*
ON
ON
5
ON
ON
OFF
*
ON
ON
6
OFF
ON
OFF
*
ON
ON
7
ON
OFF
OFF
*
ON
ON
8
OFF
OFF
OFF
*
ON
ON
* Fail Safe Mode (Switch 4)
ON = SDI Fail Door Open
OFF = SDI Fail Door Close
Switch Settings
Switches on the D9210B assign a unique
address (1 to 8) to each module. See the
D9210B Program Entry Guide (74-07618-000)
for a complete description of address switch
settings.
Table 9 shows the correct switch setting for each
D9210B address.
Table 9: Access Control Module Address Switch
Settings
www.PDF-Zoo.com