External power operating. When using the external
power supply the battery level indicator is replaced
by the external power icon.
If the Smart Interrupter connection
cables become damaged, they should
be returned to an Authorised Service
Center for replacement.
Cleaning
Wipe down with a moist cloth.
Maintenance
There are no user serviceable
parts within the equipment.
Specifications
This equipment is intended to be connected to a secondary source
isolated from CATII 300Vrms mains by reinforced insulation
CP Current Output:
Model 50AG 50A /100V peak (Continuous)
Model 100AG 100A /100V peak (Continuous)
Frequency (of CP
system being switched): DC to 60Hz
Connection Outputs:
CP supply
CP switched
External Power
Switching Patterns:
On/Off Time 0-100s
0.1 sec increments up to 10 secs
Synchronisation:
Master Slave 100ms in 12 hour period
GPS (option) +/- 4ms
Batteries:
2 x 1.5V D cells
300 hours @ 20°C
CP Power:
Will run from CP supply if above 5V
Environmental: IP56
Temperature:
14°F (-20°C) to140°F (60°C)
Humidity:
80% up to 31°C decreasing to 50% at 40°C
Altitude:
Up to 2000m
Dimensions:
12" (300mm) x 6" (150mm) x 3" (80mm)
Weight:
2.5kg (5.5lb)
Compliance:
2004/108/EC, 1999/5/EC (GPS Option),
2006/95/EC, FCC CFR Part 15