Error messages and the representation of important sizes
Er01 – Safety thermostat 1 is activated (this can appear even when the boiler is off)
Er02 - Safety thermostat 2 is activated (this can appear even when the boiler is off)
Er03 – Shutting down due to the low temperature of flue gases
Er04 - Shutting down due to water overheating
Er05 – Shutting down due to extremely high temperatures of flue gases
Er06 – The signal of pellets temperature sensor stopped working
Er07 – The error of the encoder. There is no signal from the encoder.
Er08 – The encoder is signalizing a wrong rotation speed.
Er09 – Low water pressure.
Er10 – High water pressure.
Er11 – The error signalizing real-time clock problem in the automatic controls system
Er12 – Shutting down due to a failed ignition
Er14 – Pressure sensor read an above-threshold value (appears only when at least one of the
fans is on)
Er15 - Shutting down due to the power outage longer than 50 min
Er16 – RS 485 Communication error
Er18 – Pellets tank is empty
Er20 –
Grate
sensor error (closed contact when the system is in Pellets mode)
Er23 – Sanitary water sensor
Er25 – Cleaning engine malfunctioned (Cleaning Engine)
Er34 – Pressure dropped below the minimally allowed value limit
Er35 – Pressure is above the maximally allowed value limit
Miscellaneous messages
Sensor
The sensor shows the temperature sensor status (one or more, depending on how
many are installed). A message was shown during the checking phase and shows
whether the value shown by that probe is minimum or maximum (depending on
the type of probe). It is checking whether the probe is open/detached or loosely
connected. When the probe is open, it shows the minimum temperature from
that range. When the probe is loosely attached, it shows the maximum
temperature from that range.
Service
Service Message saying the boiler worked a certain number of hours, defined
in advance by the parameter
T66.
Call a maintenance person..
Cleaning
Cleaning Message saying the boiler worked a certain number of hours, defined
advance by the parameter
T67.
The boiler needs to be cleaned..
Block
Message appears in phases after the sub-phase
Preload (Ignition)
if the boiler was not shut down manually
Door
Door is open
Link Error
The communication between lambda panel and keyboard/screen is locked.
Transfer
Loading new parameters failed. Try again.
Failed
Failed.
Summary of Contents for TKAN Integra Series
Page 25: ...25 Slika 14 Brzi pristup nekim funkcijama sistema Slika 15 Rad sistema bez gre ke...
Page 27: ...27 Slika 18 Prikaz funkcija ekrana...
Page 71: ...71 Picture 14 Quick access to some system functions Picture 15 System operating without error...