table for every power. This space is needed in case of any bigger interventions on the pellets
feeder mechanism, 11, more precisely when it should be dismantled from the boiler. The space
at the back of the boiler (TKAN 80 and TKAN 100 Integra) needs to provide easy access to a
chimney and ash cleaning holes on it. Speaking of other boilers in this line, the space at the
back should enable handling the multi cyclone. In front of the boiler, it is necessary to ensure
easy opening of all doors and space for dedusting elements.
Picture 3. Positioning the boiler in the boiler room
DIMENSIONS
Boiler type
A* (mm)
B (mm)
C (mm)
D (mm)
TKAN 80 Integra
500
400
1000
800
TKAN 100 Integra
500
400
1000
800
TKAN 150 Integra
500
550
1000
1000
TKAN 200 Integra
600
650
1000
1000
TKAN 250 Integra
600
900
1000
1100
TKAN 300 Integra
600
900
1000
1100
Tabel 2. Positioning the boiler in the boiler room