61
-
Maxiumum pressure from 9 bars to 10 bars
-
The compressor has to have minimum airflow of 200 L/min
-
the FRL unit that meets ISO standard ISO 85731, class 14.1 (separation of solid
particles, moisture and oil)
-
Manometer
1. It is mandatory to release water once a day from the compressor’s tank by using valve
at the bottom of the tank.
2. It is mandatory to empty the bowl of the FRL unit where condensation (water)
accumulates. If a compressor does not have a tank of 200l in capacity.
Unit B:
Obtained by a buyer.
* Ensure at least the 200l tank. For the purpose of continual air supply for the unit C.
***This is necessary only if the compressor does not have its own tank of at least 200l. This
tank has to be certified to working pressure of 10 bars, test pressure of at least 13bars and has
to have safety valve on it set tuned to 10 bars. It can be horizontal or vertical.
The air tank and safety valve have to be certified. The user of the equipment under
pressure is obliged to control the tank and safety valve, regulated by the examination and
inspection rulebook for the equipment under pressure.
It is mandatory to release water from the tank daily by using the valve located at the
bottom of the tank.
Unit C:
is an integral part of the boiler and is comprised of:
-
the air tank,
-
the tank carrier,
-
the safety valve,
-
the relief valve 1/2",
-
the manometer 1/4",
-
the quick-release coupling 1/2" SN,
-
the connection for quick-release coupling 1/4" UN,
-
the connection for the hose 10/8 1/4" SN,
-
the pulse valves carrier,
-
pulse valves 6/4“,
-
connecting elements (clamps, rubber hoses, and connections),
-
micro switch.
All elements of unit C are provided by a manufacturer:
The air tank and safety valve must be
certified. The user of pressure equipment is
obliged to perform the control of tanks and
safety valves, which is regulated by the
rulebook on inspections and testing of
pressure equipment.