P26 [selection of configuration] =10;
P75 [DHW Temperature sensor] =8;
P76 [Buffer temperature sensor] =9;
P36 [configuration of pump] =14
Parameters Th18, Th19, Th20, Th21, Th57, Th79 are found in the system menu
Thermostats menu and
should be adjusted to the needs of the user and the instruction above.
7.6.6 List of temperature parameters/thermostats
Code
Description
Probe
Unit
Th18
Anti-freeze protection
S1
[°C]
Th19
Activation pump thermostat
S1
[°C]
Ih19
Activation Pump Thermostat Hysteresis
S1
[°C]
Th21
Sanitary 2 Thermostat
S1
[°C]
Ih21
Water Boiler Thermostat Hysteresis 2
S1
[°C]
Ih24
Water Boiler Thermostat Hysteresis
S1
[°C]
Th25
Boiler Safety Thermostat
S1
[°C]
Th26
Boiler Thermostat minimum range
S1
[°C]
Th27
Boiler Thermostat maximum range
S1
[°C]
Th51
Minimum temperature which the user may set in the buffer
S2
[°C]
Th52
Maximum temperature which the user may set in the buffer
S2
[°C]
Th57
Difference between the temperature of water in the boiler and water
in the buffer
Dif.
[°C]
Ih57
Differential Thermostat Th57 Hysteresis
Dif.
[°C]
Ih58
Buffer Thermostat Hysteresis
S2
[°C]
Th59
Temperature at which Pump P2 is activated
S2
[°C]
Ih59
Thermostat Th59 Hysteresis
S2
[°C]
Th60
Boiler Return Differential 2 Thermostat Hysteresis (valid only for
configuration 8)
Ret. Boiler
[°C]
Ih60
Boiler Return Thermostat Hysteresis
Ret. Boiler
[°C]