Radijator Inženjering d.o.o, 36000 Kraljevo, Živojina Lazića - Solunca br.6, Srbija
tel. +381 36 399 140, fax. +381 36 399 150, http://www.radijator.rs
e-mail: [email protected]
81
Fan Calibration
Menu to change the Combustion Fan speed. The system has 10 calibration’s steps (the 0
value is set by the factory). The calibration’s effect is valid only in Run Mode and
Modulation for the current recipe. For each step the value is increased in percentage for
the value P16.
Example:
P16
=5%, Step= +3
Default
values
U03=1000 U04=1200 U05=1400
U06=1600
U07=1800
U11=900
Calibrated
values
U03=1150
U04=1380
U05=1610
U06=1840
U07=2070
U11=1030
Heating
Management
Boiler Thermostat
Menu which allows to modify the Boiler Thermostat’s value.
*If it is possible to manage the outdoor temperature sensor, this menu is not
available because water temperature is automatically calculated.
Buffer Thermostat*
Menu which allows to modify the Buffer/Top Buffer Thermostat’s value.
Bottom Buffer Thermostat**
Menu which allows to modify the Bottom Buffer Thermostat’s value.
DHW Thermostat*
Menu which allows to modify the Domestic Hot Water thermostat value.
Flow Thermostat*
Menu which allows to modify the Flow thermostat’s value in configuration 9.
Room Thermostat*
Menu which allows to modify the Room Thermostat’s value in the boiler room.
Summer-Winter
Summer or winter operating modality of the boiler.
Climatic Function* (Outdoor temperature sensor)
Menu to manage the climatic function, i.e. to modify outdoor temperature sensor.
Menu has two submenus, Enable and Comfort Function.
Enable: allows the user to enable/disable the outdoor temperature sensor.
Comfort Function: allows to correct the calculated thermostat by ±20 °C. Outdoor
temperature sensor works only in Winter mode. If he function is enabled, the
symbol
is shown on the display.
Mixer Valve*
Menu to manage the Mixer Valve.
It is possible to regulate it in automatic mode or
force it to open or close.
*Appearance of these values on the display depends on the configuration in which the boiler works.
For more information, address a professional.