Installation Manual
Gas Fire Heater – Cod. 99962NA – November 2002
2
TECHNICAL SPECIFICATION
Type C device
Type C devices are devices in which the combustion circuit (air intake, combustion
chamber, exchanger, combustion exhaust) is sealed off from the place where they
are installed
.
CENTRAL HEATING – D.H.W.
room sealed circuit type
mod.
RBS 20 E
Technical data
Model
SF 16 E
KW
BTU/h
Maximum Rated Output
25
85275
Maximum Rated Output
13.2
45025
Maximum Rated Input
29.7
101308
Maximum Rated Input
16.3
55599
Efficiency 84
%
Gas Type
Methane Gas
Liquid Gas (LPG)
(G20) (G30) (G31)
Lower Wobbe Index (at 15°C - 1013 mbar) MJ/m
3
34.02 0116.09 88
MJ/Kg.
45.65
46.34
Rated Feed Pressure mbar (mmCA)
20 (204)
30 (306)
37 (377)
Consumption m
3
/h
3.14
Kg/h
2.34
2.30
Burne Nozzle Ø mm
1.25
0.75
Gas Connections
1/2”
1/2”
Acqua
Minimum Pressure bar.
0.4
Normal Pressure bar.
2
Maximum Pressure bar.
6
Temperature Adjustment °C
40 °C - 60 °C
Domestic Hot Water Maximum Flow
∆
t 25 °C / 15t/min
Water Connextions
1/2”
Flue Diameter mm
100/60 KIT A - 80/80 Kit B
Power Supply W
70
Fuse A
1
Electrical Connection V/Hz
230 / 50
Dimension and Weights
Water Heater
Packing
Height mm
710
750
Width mm
480
530
Depth mm
240
285
Weight Kg
24
26
Coaxial vertical
Coaxial horizontal
C32
C12
C52 Double