MALFUNCTION

 

POSSIBLE CAUSE

 

REMEDY 

 

 

The water heater doesn’t work        
Gas and water tap opened       
Power indicator ON         
D. Hot Water operation indicator OFF

 

 

 
_

Rotative flow meter  

_D. Hot Water 1/8” sensor  
_Fuse      
_Main Circuit Board  (See table 1) 

 

 
_

Replace it  

_Replace it    
_Replace it  
_Replace it 

 

 
The water heater doesn’t work  
Power indicator ON     
D. Hot Water operation indicator  ON   
 

 
_High temperature limit 
thermostat  
_Exhaust fan  
_Electronic ignition board faulty  

 
_Replace it   
_Replace it  
_Replace it   

 
Power indicator ON  
D. Hot water operation indicator ON 
Exhaust fan working  
but  flame doesn’t ignite and the water 
heater doesn’t lock-out.  

 
_Air pressure switch  
_Air intake flue pipe obstructed  
  
_Electronic ignition board faulty  
         

 
_Replace it  
_Clean the flue pipe  
 
_Replace it  
         

 
Power indicator ON          
D. Hot water operation indicator ON  
Exhaust fan working             
The flame ignites but after 10 seconds the 
water heater locks out.   

 
_Line / Neutral polarity reversed  
_Ionisation electrode       
 
_Ionisation electrode lead  
_Electronic ignition board  

 
_Reverse polarity          
_Check and adjust the electrode  
  position  
_Replace it      
_Replace it  

 
Power indicator ON   
D. Hot water operation indicator ON      
Exhaust fan working  
The ignition electrode sparks but does not 
ignite the burner and after 10 seconds the 
water heater locks-out. 

 
_Ignition electrode in bad position  
_Electronic ignition board faulty  
_Gas valve faulty  
_insufficient fuel (gas)  

 
_Check that the distance from the 

burner is  2.5 / 3 mm 

_Replace it   
_Replace it 
_Open the gas tap   
         

 
The water heater always runs at minimum 
output 
 

 
_Modulator lead broken or 
disconnected 
 _Modulator calibrated incorrectly  
_Flow meter calibrated incorrectly  

 
_Replace or connect it       
_Calibrate it      
 
_Calibrate it           

 
 

 

 

ON THE MAIN PRINTED CIRCUIT BOARD CHECK THAT ON FLOW 
METER TERMINAL THERE IS VOLTAGE  AMONG GREEN - WHITE AND 
GREEN - RED LEADS. 
THE MEASUREMENTS MUST BE DONE WHILE THE WATER HEATER IS 
WORKING.

 

FLOW METER 

FAULTY 

GUASTO

D.H.W. SENSOR 

FAULTY  

GUASTA

GREEN    

 

P.C.B. OR FUSE 

FAULTY 

 

GREEN 

 

GREEN    

 

WHITE

 

RED 

 

RED  

 

WHITE 
O

RED 

 

WHITE

 

0 V

 

12 V

 

12 V

 

6 V

 

0 V

 

0 V

 

Table 1                             MALFUNCTIONS DIAGRAM 

 

Summary of Contents for SF 16 E

Page 1: ...CE 0694 ENGLISH Technical Specification RADIANT BRUCIATORI S p A Montelabbate PU ITALY By Technical Department INSTALLATION AND MAINTENANCE MANUAL FOR GAS FIRED HEATER Model SF 16 E TYPE C ROOM SEALED...

Page 2: ......

Page 3: ...EM page 3 GENERAL INSTALLATION REQUIREMENTS page 5 BOILER INSTALLATION page 6 GAS OPERATIONS AND ADJUSTMENTS page 8 REGULATING THE GAS PRESSURE page 9 ELECTRICAL CONNECTIONS page 10 12 BOILER CONTROL...

Page 4: ...h an expansion vessel 2 WARNINGS REGARDING INSTALLATION Warranty expires 12 months from date of installation and in all cases no later than 18 months from date of construction First start up must be p...

Page 5: ...Gas Type Methane Gas Liquid Gas LPG G20 G30 G31 Lower Wobbe Index at 15 C 1013 mbar MJ m3 34 02 0116 09 88 MJ Kg 45 65 46 34 Rated Feed Pressure mbar mmCA 20 204 30 306 37 377 Consumption m3 h 3 14 Kg...

Page 6: ...mes into flue duct and emission of air from outside N B To insert a flue bend reduce total length of flue by 0 5 m NOTE USE ORIGINAL RADIANT APPROVED FLUE KIT SYSTEMS FLUE ACCESSORIES AND FLUE DIAPHRA...

Page 7: ...nal dynamic pressure of 20m Bar 8 in wg at the boiler Installation pipes should be fitted in accordance with BS6891 1988 Pipework that supplies the boiler must be a 22 mm ininterrupted supply from met...

Page 8: ...onditioning systems If this should occur the appliance MUST BE TURNED OFF IMMEDIATELY and the local gas region consulted Where the lowest part of the terminal is fitted less than 2m 6 6ft above a balc...

Page 9: ...WALL The installation and fixing to wall of the water heater must conform to the national standards and safety norms Follow these instructions 1 With a spirit level min length 40 cm draw a line on the...

Page 10: ...ensions on p 5 Check the internal and external seal of the gas feed system If the unit is not used for an extended time close the main gas feed cock Conversion of the unit from Nat Gas to LPG must be...

Page 11: ...tors must be installed with new gaskets Reassemble the entire burner unit Attention after every disassembly and re assembly of gas connections check carefully with soap and water 3 Move the selector l...

Page 12: ...ctor back fig 2 to its original position Tighten the aluminium cap of the regulator remove the pressure gauge fig 3 and tighten the B pressure point screw Gas type Natural Gas Liquid gas LPG G20 G30 G...

Page 13: ...l as follows A Turn off the electrical power supply at the mains B Remove the boiler front casing C Undo the two side screws on the panel using the VT screwdriver and turn it to the position shown in...

Page 14: ...On off SENSOR INTERRUPTED OFF R 45Kohm ON R 45Kohm On off 0 PWM LINK FOR MINIMUM OUTPUT ADJUSTMENT NO CONTACT OK FAN OVER RUN TIME 8 min P1 0 CHECK PA 0 100 MIN OUTPUT CAP GPL P3 PWM SIGNAL GENERATOR...

Page 15: ...SENSOR CVI m MODULATION SIGNAL SP PWM BLACK LIMIT THERMOSTAT POWER SWITCH TEMPERATURE SENSOR POWER OM INDICATOR KEY IGNITION ON INDICATOR ST TL IG LT LF N NEUTRAL L LINE ST RED WHITE GREEN BLACK ROTAT...

Page 16: ...p Shut down requires manual resetting to restore operation wait ten seconds and then push reset button 5 Re ignition is provided if the main burner accidentally shuts down The heater will shut down if...

Page 17: ..._Line Neutral polarity reversed _Ionisation electrode _Ionisation electrode lead _Electronic ignition board _Reverse polarity _Check and adjust the electrode position _Replace it _Replace it Power in...

Page 18: ...up B Remove the tape and open the 4 flaps toward the outside C Remove the inside cardboard packing D Hold the water heater from the rear frame when lifting IMPORTANT The packing material cardboard is...

Page 19: ......

Page 20: ...1329 828555 All descriptions and illustrations contained in this leaflet have been carefully prepared but we reserve the right to make changes and improvements in our products whitch may affect the ac...

Reviews: