Installation Manual 

Gas Fire Heater  – Cod. 99962NA – November  2002

 

 

THE FRIENDLY POWER OF HEAT 

 

Thank you for choosing RADIANT 
 

Declaration for purposes of Art. 7 of Law 46 of 5 April 1990. 

RADIANT BRUCIATORI S.p.A. hereby declares that all of its products are constructed to industry standards as required by the Article in question and by Article 
5 of the law in effect (D.P.R. no. 447/97). 
 

RADIANT BRUCIATORI S.p.A.

 products are type tested 

EC.

 

 
All 

RADIANT

 boilers are constructed according to UNI - CIG 

(EC)

 norms. The materials used, such as copper, brass, and stainless steel form a compact, 

homogeneous, highly functional unit that is easy to install and simple to operate. The wall-mounted boiler is equipped with all of the approved accessories 
required to make it a true, independent heating plant for home heating and for the production of hot water for domestic needs. All boilers are fully inspected, 
and come with a certificate of quality signed by the inspector and with a warranty certificate. This booklet must be read carefully and stored in a safe place, 
accompanying the boiler at all times

 
RADIANT BRUCIATORI S.p.A. declines any and all responsibility for misinterpretations of this booklet deriving from any translations of same. 
RADIANT BRUCIATORI S.p.A. will not be responsible for non-observance of the instructions contained in this booklet or for the consequences of 
any action not specifically described herein.

 

 

INSTALLATION INSTRUCTIONS  - WARNINGS  

 

THIS INSTALLATION, USE, AND MAINTENANCE MANUAL IS AN ESSENTIAL AND INTEGRAL PART OF THE PRODUCT, AND MUST ALWAYS BE KEPT NEAR THE DEVICE. 
THE WARNINGS CONTAINED IN THIS SECTION ARE ADDRESSED BOTH TO THE USER AND TO INSTALLATION AND MAINTENANCE PERSONNEL. 
THE USER WILL FIND INFORMATION ON OPERATION AND LIMITS OF USE IN THE ACCOMPANYING MANUAL, WHICH SHOULD BE READ VERY CAREFULLY. 
STORE THE MANUAL CAREFULLY FOR FUTURE REFERENCE

 
1) GENERAL WARNINGS  
INSTALLATION MUST BE PERFORMED IN OBSERVANCE OF CURRENT NORMS, ACCORDING TO THE CONSTRUCTOR’S INSTRUCTIONS, AND BY PROFESSIONALLY QUALIFIED PERSONNEL. 
THE INSTALLATION INSTRUCTIONS MANUAL MUST BE ALWAYS ACCOMPANY THE BOILER. 
PROFESSIONALLY QUALIFIED PERSONNEL ARE THOSE HAVING TECHNICAL COMPETENCE IN THE SECTOR OF APPLICATION OF THE DEVICE (CIVIL OR INDUSTRIAL), AND, IN PARTICULAR, THE CONSTRUCTOR’S 
AUTHORISED SERVICE CENTRES. 
INCORRECT INSTALLATION MAY CAUSE DAMAGE TO PERSONS, ANIMALS, OR PROPERTY, FOR WHICH THE CONSTRUCTOR ASSUMES NO LIABILITY. 

• 

After completely removing the packing, make sure that the contents are in perfect condition. 

• 

In case of doubt, do not use the equipment. Consult the supplier. 

• 

Packing materials (cardboard carton, wooden crate, nails, clips, plastic bags, polystyrene, etc.) are potentially dangerous and must be kept away from children. 

• 

Before performing any cleaning or maintenance operation, turn off the unit by means of the mains switch and/or by means of the appropriate cut-off devices. 

• 

Do not block the air intake or heat dissipation grates. 

• 

In the event of breakdown and/or poor functioning of the device, turn it off and do not attempt to repair it or take any direct action. Refer to professionally qualified personnel only. 

• 

Any repairs must be performed exclusively by a service centre authorised by the constructor, and with original spare parts only. 

• 

Non-observance of the above instruction may compromise the safety of the device. To guarantee efficient and correct operation, the device should undergo period maintenance by professionally qualified personnel according to 

the constructor’s instructions. 

• 

Whenever the device is to be put out of service, secure all potentially hazardous parts to prevent accidents or damage. 

• 

If the device is sold or transferred to another owner, or if you move and leave the boiler, make sure that this booklet stays with the boiler so that it may be consulted by the new owner and/or by the installer. 

• 

Use only original spare parts for all devices with optionals or kits (including electrical ones). 

 

WARNING

: this device must be used for its intended purpose, i.e., heating and production of domestic hot water. Any other use is improper and therefore dangerous. The constructor will have no contractual or extracontractual liability for 

damage caused by incorrect installation and/or use or by non-observance of instructions supplied by the constructor. 
 

This device must be used exclusively with a sealed central heating system equipped with an expansion vessel. 

 

2) WARNINGS REGARDING INSTALLATION

 

Warranty expires 

12 months from date of installation and in all cases no later than 18 months from date of construction

. First start-up must be performed by 

authorised personnel only

. For any operation on the hydraulic, gas, or 

electrical circuit regarding the heating unit, refer to 

authorised technicians only

 

and use original spare parts only

. Wall-mounted boilers are not to be installed in damp rooms, and must be protected against sprays or jets of water or 

other liquids to prevent malfunctions of the electrical and heating devices. They must not be exposed to direct steam from cookers, and nothing must be placed on top of them. This heating unit has been constructed to heat the home and 
to produce hot water. 

The constructor declines all responsibility for incorrect installation and/or use of the device.

 Do not leave the device on when it is not being used: 

close the gas cock and turn off the mains switch

. If you 

smell gas in the room in which the device is installed, do not operate any electrical switches, telephones, or any other device that might cause a spark. Immediately open doors and windows to create an air current to clear the room. Close 
the main gas cock (at the meter) or the cylinder cock, and request immediate technical service. 

Do not tamper with the device. 

 

SYSTEMS WITH THERMOSTATS 

 
A by-pass must be installed in heating systems with radiators thermostats. 
As required by current norms, these devices must be installed by 

qualified personnel only

, who must respect norms 

UNI-CIG 7129 and 7131

 and revisions, fire department regulations, and requirements of the local gas company. Before 

installing the boiler, make sure that the water and heating systems are compatible with its output. The room must be properly ventilated by means of an air intake (see UNI 7129/92 and UNI 7129/95 FA). 
The air intake must be at floor level open flue only, at a point where it cannot be obstructed, and protected by a grate that does not reduce the useful section of flow. 
The use of air flows from adjacent rooms is permitted as long as such rooms are in depression with respect to the outside and as long as there are 

no wood-burning fireplaces or fans

 installed there. If the boiler is to be installed 

externally (for example, on balconies or terraces), make sure that it is protected against atmospheric agents to prevent damage to components and voiding of the warranty. In such cases we recommend building a heat compartment to 
protect the boiler against inclement weather. 

Check the technical data on the packing and on the plate

 located inside the front casing. Check that the burner is suitable for use with the type of gas available. 

Make sure that all pipes and connections are perfectly sealed and that there are no gas leaks.

 

All pipework should be chemically flushed to remove any residues that might negative effect the operation of the boiler. 
 

3) GENERAL WARNINGS BASED ON TYPE OF POWER SUPPLY 

POWER  SUPPLY           

    

Electrical safety is achieved only when the device is correctly and efficiently earthed as per current safety norms (IEC 64-8 Electrical Part). 

• 

This fundamental safety requirement must be checked. In case of doubt, request a check of the electrical system by professionally qualified personnel. The constructor will not be liable for any damage caused by lack of or 

improper earthing of the system. 

• 

Have professionally qualified personnel check that the electrical system is adequate for the maximum absorbed power of the device (indicated on the plate). In particular, make sure that the section of the system wires is suitable 

for the maximum absorbed power of the device. 

• 

Do not use adapters, multiple sockets, and/or extension cords to power the device from the electrical mains. 

• 

Provide a unipolar switch as required by current safety regulations to connect the device to the mains. 

• 

The use of any electrical device requires the observance of some fundamental rules, such as: 

• 

do not touch the device with wet or damp parts of the body and/or with bare feet 

• 

do not pull on electrical cables 

• 

do not expose the device to atmospheric agents (rain, sun, etc.) unless specifically provided for 

• 

do not allow the device to be used by children or anyone unfamiliar with its operation 

• 

The power cable must not be replaced by the user. 

• 

If the cable becomes damaged, turn off the device and have the cable replaced by professionally qualified personnel only. 

• 

If you decide not to use the device for an extended length of time, turn off the mains switch that feeds all components of the system using electrical energy (pumps, burner, etc.). 

Summary of Contents for SF 16 E

Page 1: ...CE 0694 ENGLISH Technical Specification RADIANT BRUCIATORI S p A Montelabbate PU ITALY By Technical Department INSTALLATION AND MAINTENANCE MANUAL FOR GAS FIRED HEATER Model SF 16 E TYPE C ROOM SEALED...

Page 2: ......

Page 3: ...EM page 3 GENERAL INSTALLATION REQUIREMENTS page 5 BOILER INSTALLATION page 6 GAS OPERATIONS AND ADJUSTMENTS page 8 REGULATING THE GAS PRESSURE page 9 ELECTRICAL CONNECTIONS page 10 12 BOILER CONTROL...

Page 4: ...h an expansion vessel 2 WARNINGS REGARDING INSTALLATION Warranty expires 12 months from date of installation and in all cases no later than 18 months from date of construction First start up must be p...

Page 5: ...Gas Type Methane Gas Liquid Gas LPG G20 G30 G31 Lower Wobbe Index at 15 C 1013 mbar MJ m3 34 02 0116 09 88 MJ Kg 45 65 46 34 Rated Feed Pressure mbar mmCA 20 204 30 306 37 377 Consumption m3 h 3 14 Kg...

Page 6: ...mes into flue duct and emission of air from outside N B To insert a flue bend reduce total length of flue by 0 5 m NOTE USE ORIGINAL RADIANT APPROVED FLUE KIT SYSTEMS FLUE ACCESSORIES AND FLUE DIAPHRA...

Page 7: ...nal dynamic pressure of 20m Bar 8 in wg at the boiler Installation pipes should be fitted in accordance with BS6891 1988 Pipework that supplies the boiler must be a 22 mm ininterrupted supply from met...

Page 8: ...onditioning systems If this should occur the appliance MUST BE TURNED OFF IMMEDIATELY and the local gas region consulted Where the lowest part of the terminal is fitted less than 2m 6 6ft above a balc...

Page 9: ...WALL The installation and fixing to wall of the water heater must conform to the national standards and safety norms Follow these instructions 1 With a spirit level min length 40 cm draw a line on the...

Page 10: ...ensions on p 5 Check the internal and external seal of the gas feed system If the unit is not used for an extended time close the main gas feed cock Conversion of the unit from Nat Gas to LPG must be...

Page 11: ...tors must be installed with new gaskets Reassemble the entire burner unit Attention after every disassembly and re assembly of gas connections check carefully with soap and water 3 Move the selector l...

Page 12: ...ctor back fig 2 to its original position Tighten the aluminium cap of the regulator remove the pressure gauge fig 3 and tighten the B pressure point screw Gas type Natural Gas Liquid gas LPG G20 G30 G...

Page 13: ...l as follows A Turn off the electrical power supply at the mains B Remove the boiler front casing C Undo the two side screws on the panel using the VT screwdriver and turn it to the position shown in...

Page 14: ...On off SENSOR INTERRUPTED OFF R 45Kohm ON R 45Kohm On off 0 PWM LINK FOR MINIMUM OUTPUT ADJUSTMENT NO CONTACT OK FAN OVER RUN TIME 8 min P1 0 CHECK PA 0 100 MIN OUTPUT CAP GPL P3 PWM SIGNAL GENERATOR...

Page 15: ...SENSOR CVI m MODULATION SIGNAL SP PWM BLACK LIMIT THERMOSTAT POWER SWITCH TEMPERATURE SENSOR POWER OM INDICATOR KEY IGNITION ON INDICATOR ST TL IG LT LF N NEUTRAL L LINE ST RED WHITE GREEN BLACK ROTAT...

Page 16: ...p Shut down requires manual resetting to restore operation wait ten seconds and then push reset button 5 Re ignition is provided if the main burner accidentally shuts down The heater will shut down if...

Page 17: ..._Line Neutral polarity reversed _Ionisation electrode _Ionisation electrode lead _Electronic ignition board _Reverse polarity _Check and adjust the electrode position _Replace it _Replace it Power in...

Page 18: ...up B Remove the tape and open the 4 flaps toward the outside C Remove the inside cardboard packing D Hold the water heater from the rear frame when lifting IMPORTANT The packing material cardboard is...

Page 19: ......

Page 20: ...1329 828555 All descriptions and illustrations contained in this leaflet have been carefully prepared but we reserve the right to make changes and improvements in our products whitch may affect the ac...