USER INSTRUCTIONS
RK 55 - RAD - ING - MAN.UT – 1311.1 - DIGITECH CS MIAH4
5
6. Filling the system
In order to restore the water pressure of the system, open the external filling loop valve and check by means of a
pressure gauge
,
that the pressure of the system reaches 1.2 ÷ 1.5 bar.
On completion, close the external filling loop valve.
After the water pressure is restored, a purging cycle of 2 minutes is automatically performed by the boiler. The
function code
F33
will appear on the display. The starting of the boiler is enabled only once the purging cycle has
been completed.
7. Diagnostics – Error and function codes
This paragraph contains a list of error
Exx
and function
Fxx
codes that the boiler may generate on the display
together with the relative indications and the operations that the user can carry out to reset the boiler.
Error codes
Code
E01
Ionisation malfunction.
(
associated symbol)
Check that the gas valve on the boiler and gas meter are open. and that there is gas in the mains supply.
Press Reset button
‘
’ on the control panel to reset the error;
When the error code on the display disappears, the boiler will restart automatically.
If the problem persists,
Call the Service Centre
.
Code
E02
Safety Thermostat tripped
.
(
associated symbol)
Press Reset button
‘
’ on the control panel to reset the error;
When the error code on the display disappears, the boiler will restart automatically.
If the problem persists,
Call the Service Centre
.
Code
E03
Thermo fuse 102 °C tripped.
(
associated symbol).
Call the Service Centre.
Code
E04
Water Pressure Switch Tripped
(
associated symbol).
Check the water pressure in the central heating circuit. The reading on the pressure gauge
M
(see fig. 2), located
on the lower part of the boiler, must not be less than 1,2 bar.
If the pressure is less than 1,2 bar, top-up the system as described in paragraph “Filling the system”.
When the error code on the display disappears, the boiler will restart automatically.
If the problem persists,
Call the Service Centre
.
Code
E05
Heating Sensor malfunction
.
(
associated symbol ).
Call the Service Centre.
Code
E06
D.H.W sensor malfunction.
(
associated symbol ).
(RS version only - with connection to a
remote storage cylinder). Call the Service Centre.
Code
E16
Fan malfunction.
(
associated symbol ).
Call the Service Centre.