USER INSTRUCTIONS
RK 55 - RAD - ING - MAN.UT – 1311.1 - DIGITECH CS MIAH4
3
3. Starting up the boiler
Check that the boiler is power supplied and that the gas feed valve, placed at the bottom of the boiler, is
open.
Switch on the boiler by using MODE SELECTION
BUTTON
and select the functioning mode
required.
4. INFO Menu display
Press the ‘
’ INFO Button to display the boiler data.
Once pressed, the parameter number will appear on the left side of the display and the associated
parameter value will appear on the centre of the display. Use ‘
’ and ‘
’ buttons of
Heating
Temperature setting to scroll the list of available data.
Press the ‘
’ INFO button to exit the display mode.
The list of available display data is the following:
Parameter Icon Description
d00
DHW sensor temperature
(RS version only - with connection to a remote storage cylinder)
d01
Outdoor sensor temperature
[only with outdoor temperature sensor]
d02
Kd
Thermoregulation value
(
the climatic compensation curve)
[only with outdoor temperature
sensor]
d03
Fan speed
d04
Low temperature circuit sensor è [
only with Zone PCB connected]
d05
Heating return sensor temperature
[only with
return sensor temperature]
d06
Solar panel sensor temperature
[only with Solar PCB connected]
d07
Solar storage cylinder temperature (low level) [
only with Solar PCB connected]
d08
Solar storage cylinder temperature (high level)
[only with Solar PCB connected]