5.  Boiler functioning modes 

 
“SUMMER” mode 

(RS version only - with connection to a remote storage cylinder)

 

To switch boiler operation to “SUMMER” mode, press the MODE SELECTION button  

 

 

(page 2, fig. 1,pos.3)

The boiler will only work for the D.H.W system, the heating system is disabled. The “SUMMER” mode setting of the 

boiler is signalled by the symbol 

, lit continuously on the control panel.  

The automatic ignition system will light the burner every time there is a domestic hot water demand. In this case, the 

symbol 

 will flash on the control panel.  

 
 
“WINTER” mode 

To switch boiler operation to “WINTER” mode, press the MODE SELECTION button  

 

 

(page 2, fig. 1,pos.3)

T

he boiler will only work for the Heating system. The “WINTER” mode setting of the boiler is signalled by the symbol 

 lit continuously on the control panel. 

The automatic ignition system will light the burner every time there is a room heating demand. In this case, the 

symbol 

 will flash on the control panel. 

 
 
“SUMMER-WINTER” mode 

(RS version only - with connection to a remote storage cylinder)

 

To switch boiler operation to “SUMMER-WINTER” mode, press the MODE SELECTION button  

 

 

(page 2, fig. 

1,pos.3)

. The boiler will work for both central heating/D.H.W systems. The “SUMMER-WINTER” mode setting of the 

boiler is signalled by symbols 

 lit continuously on the control panel. 

The automatic ignition system will light the burner every time there is a room heating or domestic hot water demand. 

The functioning is signalled by the symbols 

 flashing continuously on the control panel

.

 

 

 
Regulating the heating temperature 

The heating temperature is regulated by using  ‘

’ and ‘

’ buttons of 

Heating temperature setting 

 

(page 3, 

fig. 1,pos.1)

.

 

 Pressing 

’ button, reduces the temperature. 

 Pressing 

’ button, increases the temperature. 

The range of temperature settings for the central heating runs from a minimum of 30°C to a maximum of 80°C (25 
°C – 45 °C for under floor heating systems). 

 

 
Regulating the D.H.W temperature 

(RS version only - with connection to a remote storage cylinder)

 

The D.H.W temperature is regulated by using  ‘

’ and ‘

’ buttons 

S

 

symbol side

 

(page 2, fig. 1,pos.5)

.

 

 Pressing 

’ button, reduces the temperature. 

 Pressing 

’ button, increases the temperature. 

The range of temperature settings for the D.H.W temperature runs from a minimum of 35 °C to a maximum of 60 
°C. 

Summary of Contents for RK 55

Page 1: ...CE 0694 RK 55 RAD ING MAN UT 1311 1 DIGITECH CS MIAH4 Technical specification RADIANT BRUCIATORI S p A Montelabbate PU ITALY ENGLISH User Manual for model RK 55 Premix condensing system boiler...

Page 2: ...Control Panel 2 3 Starting up the boiler 3 4 INFO Menu 3 5 Boiler functioning modes 4 6 Filling the system 5 7 Diagnostics Error and function codes 5 8 Switching OFF the boiler 6 9 Frost Protection 7...

Page 3: ...uthorised technician do not attempt to start it All maintenance and gas conversion operations MUST BE CARRIED OUT BY PROFESSIONALLY QUALIFIED PERSONNEL Should any part of the boiler freeze up do not a...

Page 4: ...AL WIRING 7 LCD DISPLAY LCD display icons key 1 PARAMETER NUMBER INFORMATION 2 PARAMETERS PROGRAMMING MODE ON 3 SOLAR PCB CONNECTION INFORMATION SOLAR PANEL TEMPERATURE DISPLAY d6 4 SOLAR PUMP ON 5 ST...

Page 5: ...list of available data Press the INFO button to exit the display mode The list of available display data is the following Parameter Icon Description d00 DHW sensor temperature RS version only with con...

Page 6: ...ion to a remote storage cylinder To switch boiler operation to SUMMER WINTER mode press the MODE SELECTION button page 2 fig 1 pos 3 The boiler will work for both central heating D H W systems The SUM...

Page 7: ...nel to reset the error When the error code on the display disappears the boiler will restart automatically If the problem persists Call the Service Centre Code E02 Safety Thermostat tripped associated...

Page 8: ...ts Call the Service Centre Code E35 Flame detection malfunction associated symbol Press Reset button on the control panel to reset the error When the error code on the display disappears the boiler wi...

Page 9: ...and special functions that provide the starting of the burner to heat all the interested parts when their temperature drops below the minimum preset values This function is enabled if the boiler is e...

Page 10: ...THE COMPANY RESERVES THE RIGHT TO APPLY VARIATIONS WITHOUT PRIOR NOTIFICATION NEITHER WILL THE COMPANY BE HELD RESPONSIBLE FOR ANY INACCURACIES IN THIS HANDBOOK DERIVING FROM PRINTING OR TRANSLATION E...

Reviews: