background image

USER INSTRUCTIONS 

 

RK 55 - RAD - ING - MAN.UT – 1311.1 - DIGITECH CS MIAH4

 

7

 

 

 

8.  Switching OFF the boiler 

 

 

To switch the boiler OFF, press  

 INFO button,  the symbol 

appears on the display. The frost 

protection system, the circulating pump inactivity protection and 3-way valve inactivity protection 
functions remain enabled 

(RS version only - with connection to a remote storage cylinder)

.   

 

If the boiler was previously ON, it is switched OFF and the fan overrun and pump overrun functions are 
enabled. 

 

N.B. If the boiler is to be left unused for a long period of time,

 the user must do one of the following: 

 

Make the boiler safe

 by disconnecting all the power supplies (electricity and gas), and draining the heating 

system; 

  Leave the boiler in 

OFF position, 

leaving the electricity and gas supplies connected and, consequently the frost 

protection function. 

 

9. Frost 

Protection 

 

The boiler is protected from freezing by electronic board settings and special functions that provide the starting of 

the burner to heat all the interested parts, when their temperature drops below the minimum preset values. 

 
This function is enabled if:  

–  the boiler is electrically power supplied;  
–  the gas supply is open; 
–  the system pressure is that required; 
–  the boiler is not locked out. 

  

In case of boiler parts locked out because of freezing, do not switch the boiler ON and immediately 

call the Service Centre. 
 

 

10. Maintenance 

 

In order to ensure that the boiler operates efficiently and safely, it is recommended that the appliance is inspected 
by a suitably competent technician at least once a year

.  

A regular maintenance is always source in management system savings.  

 

 

11. Recycling 

 

The appliance packaging is mainly made of 
recyclable materials.  
 
The appliance and all its accessories must be 
disposed of appropriately differentiated  
in compliance with the relevant standards.

 

 

The symbol indicates the inability to dispose of 

this product as domestic waste. 

The correct disposal of this product will help to 

prevent potential negative consequences for the 

environment and people health.

 

Summary of Contents for RK 55

Page 1: ...CE 0694 RK 55 RAD ING MAN UT 1311 1 DIGITECH CS MIAH4 Technical specification RADIANT BRUCIATORI S p A Montelabbate PU ITALY ENGLISH User Manual for model RK 55 Premix condensing system boiler...

Page 2: ...Control Panel 2 3 Starting up the boiler 3 4 INFO Menu 3 5 Boiler functioning modes 4 6 Filling the system 5 7 Diagnostics Error and function codes 5 8 Switching OFF the boiler 6 9 Frost Protection 7...

Page 3: ...uthorised technician do not attempt to start it All maintenance and gas conversion operations MUST BE CARRIED OUT BY PROFESSIONALLY QUALIFIED PERSONNEL Should any part of the boiler freeze up do not a...

Page 4: ...AL WIRING 7 LCD DISPLAY LCD display icons key 1 PARAMETER NUMBER INFORMATION 2 PARAMETERS PROGRAMMING MODE ON 3 SOLAR PCB CONNECTION INFORMATION SOLAR PANEL TEMPERATURE DISPLAY d6 4 SOLAR PUMP ON 5 ST...

Page 5: ...list of available data Press the INFO button to exit the display mode The list of available display data is the following Parameter Icon Description d00 DHW sensor temperature RS version only with con...

Page 6: ...ion to a remote storage cylinder To switch boiler operation to SUMMER WINTER mode press the MODE SELECTION button page 2 fig 1 pos 3 The boiler will work for both central heating D H W systems The SUM...

Page 7: ...nel to reset the error When the error code on the display disappears the boiler will restart automatically If the problem persists Call the Service Centre Code E02 Safety Thermostat tripped associated...

Page 8: ...ts Call the Service Centre Code E35 Flame detection malfunction associated symbol Press Reset button on the control panel to reset the error When the error code on the display disappears the boiler wi...

Page 9: ...and special functions that provide the starting of the burner to heat all the interested parts when their temperature drops below the minimum preset values This function is enabled if the boiler is e...

Page 10: ...THE COMPANY RESERVES THE RIGHT TO APPLY VARIATIONS WITHOUT PRIOR NOTIFICATION NEITHER WILL THE COMPANY BE HELD RESPONSIBLE FOR ANY INACCURACIES IN THIS HANDBOOK DERIVING FROM PRINTING OR TRANSLATION E...

Reviews: