2.2.15. FAULT SIGNALLING CODES
CODE
FAULT
POSSIBLE CAUSE
SOLUTION
RESET
E01
FLAME BLOCK
NO FLAME LIGHT UP
MANUAL RESET
(PRESS THE RESET ‘
’ KEY).
GAS MISSING;
CHECK THE ADDUCTION NETWORK;
MASS OR BROKEN START-UP
ELECTRODE;
REPLACE IT;
GAS VALVE BROKEN;
REPLACE IT;
SLOW LIGHT UP TOO LOW
ADJUSTMENT;
ADJUST MINIMUM OR SLOW LIGHT UP;
PRESSURE TOO HIGH AT THE
INPUT OF THE GAS VALVE
(ONLY FOR GPL BOILER).
CHECK THE MAXIMUM ADJUSTMENT
PRESSURE
WITH FLAME LIGHT UP
DETECTION ELECTRODE
BROKEN;
REPLACE IT;
DETECTION ELECTRODE
CABLE DISCONNECTED.
CHECK THE WIRING.
ELECTRICAL CURRENT
PHASE-PHASE
IF THE TENSION MEASURES BETWEEN
NEUTRAL AND GROUND IS ALMOST
EQUAL TO THE ONE MEASURED
BETWEEN PHASE AND GROUND, YOU
HAVE TO INSTALL A PHASE-PHASE
TRANSFORMER KIT (COD. 88021LA)
E02
SAFETY THERMOSTAT
(95°C)
THERMOSTAT
CABLE BROKEN OR
DISCONNECTED;
CHECK THE WIRING;
AUTOMATIC.
BROKEN THERMOSTAT
REPLACE IT.