31
RBS 24 - RAD - ING - Manual - 1709.1_MIAB2013_R7
2 T
abella par
ametri_MIAB2013_firm.H070C_EN
2. FIRST START-UP
SUPPOR
T
C
ENTRE
2.1.5. PARAMETER TABLE MIAB2013
PARAMETER
DESCRIPTION
RANGE
FUNCTION
P00
GAS TYPE SELECTION
ATTENTION:
READ THE INSTRUCTION IN CHAPTER ‘GAS
TRANSFORMATION’ BEFORE CHANGING THIS
PARAMETER.
000 - 001
000 = METHANE
001 = LPG
P01
ADJUSTMENT OF MAXIMUM HEATING POWER
THIS PARAMETER IS USED TO SET THE MAXIMUM
BURNER GAS PRESSURE WHEN HEATING.
TO SET THE VALUE, FOLLOW THE INSTRUCTIONS
IN THE 'GAS PRESSURE CHECK AND CALIBRATION'
CHAPTER.
000 - 100
THE VALUE IS EXPRESSED IN PERCENTAGE
(PRE-SET TO 100)
P02
STARTING STEP ADJUSTMENT
THIS PARAMETER IS USED TO SET THE BURNER GAS
PRESSURE WHEN THE BOILER IS IN THE IGNITION
PHASE.
000 - 100
THE VALUE IS EXPRESSED IN PERCENTAGE
(PRE-SET TO 40)
P03
HEATING TIMING
THROUGH THIS PARAMETER YOU CAN SET THE
MINIMUM TIME FOR WHICH THE BURNER WILL BE
TURNED OFF ONCE THE HEATING TEMPERATURE
REACHED THE USER SET TEMPERATURE.
000 - 090
VALUE EXPRESSED IN MULTIPLES OF 5
SECONDS
(PRE-SET AT 36 X 5 = 180 SECONDS)
P04
HEATING RUN-UP
THROUGH THIS PARAMETER YOU CAN SET THE TIME,
DURING START-UP PHASE, NECESSARY FOR THE
BOILER TO REACH THE MAXIMUM SET POWER IN
HEATING.
000 - 010
THE VALUE IS EXPRESSED IN MINUTES
(PRE-SET TO 1 MINUTE)
P05
POST-CIRCULATION HEATING TIMING
THROUGH THIS PARAMETER YOU CAN SET THE PUMP
DURATION OF OPERATION DURING HEATING CYCLE,
AFTER THE MAIN BURNER TURNS OFF DUE TO THE
ENVIRONMENT THERMOSTAT.
000 - 090
VALUE EXPRESSED IN MULTIPLES OF 5
SECONDS
(PRE-SET AT 36 X 5 = 180 SECONDS)
P06
POST-CIRCULATION DOMESTIC HEATING TIMING
(NOT APPLICABLE TO BI-THERMAL BOILERS)
THROUGH THIS PARAMETER YOU CAN SET THE PUMP
OPERATION DURATION ON THE DOMESTIC CIRCUIT,
AFTER THE TAP IS CLOSED.
000 - 090
VALUE EXPRESSED IN MULTIPLES OF 5
SECONDS
(PRE-SET AT 18 X 5 = 90 SECONDS)