2. FIRST START-UP
SUPPOR
T
C
ENTRE
TO ADJUST THE MINIMUM C.H. FIRE RATING
WARNING
Only continue after having calibrated the
domestic minimum power pressure.
› Access parameter 'P13' by following the
procedure indicated in the "ACCESSING AND
PROGRAMMING THE PARAMETERS" chapter
and check the gas pressure on the manometer
complies with the data indicated in the
"TECHNICAL DATA" chapter;
› If not, use the '
' and '
' keys on the domestic
heating
to change the parameter values,
expressed as a percentage, which corresponds
proportionally to the pressure indicated on the
manometer.
› Keep the '
' button pressed until the 'P01'
parameter is displayed in order to confirm the
modified value.
› Once adjustment is complete, quit the
parameters menu by pressing the '
' key. The
display will show 'OFF';
› close the gas tap, remove the manometer from
the gas valve pressure socket and tighten the
screws;
› open the gas tap, switch the boiler on and check
for any gas leaks.
TO ADJUST THE MAXIMUM C.H. FIRE RATING
› Access parameter ‘P01’ by following the
procedure indicated in the “ACCESSING AND
PROGRAMMING THE PARAMETERS” chapter
and check the matching gas pressure and
nominal firing rate required for the installation,
as per the chapter “DIAGRAM NOMINAL FIRE
RATE/GAS PRESSURES”.
› Use the ‘
’ and ‘
’ keys on the domestic
heating
to change the parameter values,
expressed as a percentage, which corresponds
proportionally to the pressure indicated on the
manometer.
› Keep the ‘
’ button pressed until the ‘P01’
parameter is displayed in order to confirm the
modified value.
› Once adjustment is complete, quit the
parameters menu by pressing the ‘
’ key. The
display will show ‘OFF’;
› close the gas tap, remove the manometer from
the gas valve pressure socket and tighten the
screws;
› open the gas tap, switch the boiler on and check
for any gas leaks.