34
RBS 24 - RAD - ING - Manual - 1709.1_MIAB2013_R7
2 T
abella par
ametri_MIAB2013_firm.H070C_EN
2. FIRST START-UP
SUPPOR
T
C
ENTRE
PARAMETER
DESCRIPTION
RANGE
FUNCTION
P14
ANTI-LEGIONELLA FUNCTION
(ONLY FOR ACCUMULATION BOILERS)
THIS PARAMETER ACTIVATES/DEACTIVATES THE
"ANTI-LEGIONELLA" HEAT TREATMENT OF THE
ACCUMULATION BOILER.
FURTHERMORE, THE
DAYS AFTER WHICH THE FUNCTION IS ACTIVATED
AUTOMATICALLY CAN BE SET. THE DEFAULT VALUE IS
7 DAYS. WHEN THE FUNCTION IS ACTIVE
, THE WATER
TEMPERATURE IN THE ACCUMULATED IS BROUGHT
TO OVER 60°C WITH A POSSIBLE RISK OF SCALDING.
KEEP UNDER CONTROL SUCH DOMESTIC HOT WATER
TREATMENT (AND INFORM THE USERS) TO AVOID
UNFORESEEABLE DAMAGES TO PERSONS, ANIMALS,
PROPERTY. A THERMOSTATIC VALVE SHOULD BE
INSTALLED AT THE DOMESTIC HOT WATER OUTLET
TO AVOID ANY BURNS.
0 - 15
0 = DISABLED
1 - 15 =
DAYS AFTER WHICH THE FUNCTION IS
ACTIVATED AUTOMATICALLY.