2. FIRST START-UP
SUPPOR
T
C
ENTRE
PARAMETER
DESCRIPTION
RANGE
FUNCTION
P12
CLIMATE COMPENSATION CURVE
(ONLY WITH EXTERNAL PROBE CONNECTED)
YOU CAN CONNECT AN EXTERNAL TEMPERATURE
PROBE (SEE CHAPTER ‘ELECTRICAL CONNECTIONS’)
THAT AUTOMATICALLY CHANGES THE DELIVERY
TEMPERATURE BASED ON THE EXTERNAL MEASURED
TEMPERATURE. THE NATURE OF THE CORRECTION
DEPENDS ON THE THERMO-ADJUSTMENT VALUE KD
SET (SEE CHART).
THE SELECTION OF THE CURVE IS DETERMINED BY
THE MAXIMUM DELIVERY TEMPERATURE TM AND THE
MINIMUM EXTERNAL TEMPERATURE TE TAKING INTO
ACCOUNT THE HOUSE INSULATION DEGREE.
THE VALUES OF THE DELIVERY TEMPERATURES TM,
REFER TO STANDARD SYSTEMS 30-80 °C OR FLOOR
SYSTEMS 25-45 °C. THE SYSTEM TYPE CAN BE SET
FROM PARAMETER P11.
000 - 030
(SET BY DEFAULT AT 30) THE NUMBERING OF
THE VALUE CORRESPONDS TO ‘KD’ CURVES
ON THE CHART (SEE CHART BELOW).
P13
ADJUSTMENT OF MINIMUM HEATING POWER
THIS PARAMETER IS USED TO SET THE MINIMUM
BURNER GAS PRESSURE WHEN HEATING.
TO SET THE VALUE, FOLLOW THE INSTRUCTIONS
IN THE 'GAS PRESSURE CHECK AND CALIBRATION'
CHAPTER.
000 - 100
THE VALUE IS EXPRESSED IN PERCENTAGE
Te (°C)
35
30
25
20
15
10
75
80
45 MAX
Tm (°C)
5
0
-5
-10
65
55
60
50
40
45
35
30
30
-15
-20
25 MIN
35
70
Kd = 0
Kd = 5
Kd = 10
Kd = 15
Kd = 20
Kd = 25 Kd = 30