2. FIRST START-UP
SUPPOR
T
C
ENTRE
PARAMETER
DESCRIPTION
RANGE
FUNCTION
P19
MODULATING PUMP MAXIMUM SPEED
(ONLY WITH MODULATING PUMP AND RETURN PROBE CONNECTED)
THROUGH THIS PARAMETER YOU CAN SET THE MAXIMUM
SPEED VALUE OF THE MODULATING PUMP DURING A REQUEST
TO OPERATE IN HEATING MODE.
70 - 100
THE VALUE IS EXPRESSED
IN PERCENTAGE
P20
CONTROL PERIOD
'
T DELIVERY-RETURN
(ONLY WITH MODULATING PUMP AND RETURN PROBE CONNECTED)
THROUGH THIS PARAMETER YOU CAN SET THE RESPONSE
TIME TO THE PUMP MODULATION.
20 - 100
THE VALUE IS EXPRESSED
IN SECONDS
P21
D.H.W STORAGE TANK TEMPERATURE SETPOINT
(FOR STORAGE BOILERS ONLY)
THROUGH THIS PARAMETER YOU CAN SET THE PRIORITY
STARTING VALUE OF THE STORAGE TANK, COMPARED TO THE
USER ADJUSTABLE D.H.W SETPOINT.
03 - 09
THE VALUE IS EXPRESSED
IN °C (PRE-SET AT 9°C)
P22
TYPE OF VISUALIZATION
00 - 01
00 = HEATING CIRCUIT
TEMPERATURE ONLY
01 = TEMPERATURE
ACCORDING TO THE TYPE
OF OPERATION (D.H.W. OR
HEATING)