A P P E N D I C E S
Series 8000™ O&M Manual
141
Switch the main breaker to the
on
position (up).
Verify that the emergency stop button is in the
out
position,
not depressed. (It is located outside of the drive cabinet, on
the right-hand side.)
Switch all circuit breakers to the
on
position (up).
Verify that the motor inverters for both azimuth and eleva-
tion power on.*
*WARNING
If any motors begin turning, hit the emergency
stop button
—
on the right, outside of the cabi-
net
—
to stop them.
Verify that all power supplies show green on the DC
“ok
power” LED.*
*WARNING
If any power supply shows red on the OVL LED,
switch its breaker off (toward the right) and trouble-
shoot.
Use the LOCAL button on the drive cabinet jog panel and en-
sure the cabinet is in REMOTE mode
—
the button
is not lit
.