A P P E N D I C E S
Series 8000™ O&M Manual
157
A-14.3
SNMP
The Simple Network Management Protocol (SNMP) allows extensive
ACU control and diagnostics via network connection. It consists of
GET and SET commands to retrieve and configure parameters and to
command actions. Radeus Labs ACUs support SNMP v1 and v2c.
SNMP typically is used for integrating the ACU into Monitor-and-
Control (M&C) systems that provide real-time system information,
fault detection, target scheduling, etc.
Figure 5-12
The SNMP option for remote control uses GET/SET commands.
Management Information Base (MIB) files define the SNMP calls that
can be issued to the ACU for remote control. A copy of these files is
located on the ACU Windows Desktop (see
C:\Users\Public\Desktop\MIBS
Updated MIB files are available for download from:
Please contact [email protected] for access.