25.2 Menu 9.2 - Configuring the motor run time
Configuring the run time allows specific targeted positions to be as-
sumed based on the run time and roller shutter position.
The run time setting must be configured if:
◆
You intend to use the ventilation position function, see page 80.
◆
You intend to use the sunshine position function (only if automatic
slat function is activated, see page 88).
◆
You intend to configure and move to any target position , see page
44.
The run time can be detected directly by the Troll Comfort or Troll
Comfort 3D or you may, for example, measure and configure it with the
help of a timer.
Measurement information and run time setting:
◆
Tubular motor run times can vary depending on temperature. For
this reason, targeted movement to a specific position is subject to
certain tolerances.
◆
The run time must be configured as precisely as possible in
order for the desired positions to be reliably assumed.
◆
The run time must be reconfigured if the end points are changed.
◆
If the run time is configured, for example, with the help of a timer,
then the speed should be measured in the up direction and approx.
10 % should be added.