Screws
Outlet Pipe to Fittings
Hot Supply
Cold Supply
3.
Make sure that the mixer is level and
central in the hole, and square to the
finished wall surface (or the control
components will not fit correctly),
then mark the positions of the fixing
screw holes on the wall.
4.
For solid walls drill two 6 mm holes
for the wall plugs.
5.
Insert the wall plugs (supplied) and
attach the mixer to the wall with the
screws provided.
Note!
For stud partition installations
alternative fixings may be required
(not supplied) to fix the mixer to the
rear face of the wall cavity or to a
timber noggin.
6.
Refer to section:
‘Solid Wall or Stud
Partition
(Using Securing Brackets -
Mounting off Front Face of Wall)
’
and
follow steps 11 to 18.
Laminated Panel
(Using Securing Brackets - Mounting on Rear Face of Panel)
Note!
For laminated panels the mixer must be positioned from the rear of the panel.
Panel thickness must be between 3 and 23 mm (if a thicker panel is used, it will be
necessary to recess the securing brackets into the rear of the panel).
Important!
Make sure that there is a minimum clearance of 62 mm behind the
laminated panel to house the mixer.
1.
Remove the two shroud
screws (retain for later use)
and remove the mixer from
the building-in shroud.
2.
Mark the position of the mixer
using the building-in shroud
as a guide.