18
1145094-W2-D
Rada V12 Concealed Shower Valve
Solid Wall or Stud Partition
(Using Securing Brackets - Mounting off Front Face of Wall)
Outlet Pipe to
Overhead Fittings
Outlet Pipe to RAC
Outlet Pipe to RAC
Cold Inlet
Hot Inlet
Thermostatic
Mixer
Alternative Pipe
Layouts
60 mm Min
24 mm Max
Finished Wall
4 mm Min
Finished Wall
Finished Wall
Surface
1.
Determine the route for the hot and
cold supply pipework and for the
outlet pipework. When connecting
to the BIV Shower Fittings it is
recommended that the outlet be
positioned above and to one side
of the mixer. This is to prevent the
flexible hose from obstructing the
shower controls.
2.
Unscrew and remove the two shroud
screws and remove the building-in
shroud and chrome trim. Retain the
screws.
3.
Determine the position of the mixer
and draw around the building-in
shroud.
4.
Mark the routes for the hot and cold
supply pipework at 108 mm centres
(
Hot - Left, Cold - Right
).
Falling Supplies:
For falling supplies
loosen the grubscrew on each elbow
using the 2.5 mm hexagon key
(supplied). Remove the elbows and
install on opposite sides. Retighten
the grubscrews.
Caution!
Do not overtighten.
Note!
Make sure that the ‘O’ seals
are correctly fitted and that the filter
plugs are positioned to the front
(i.e. Hexagonal key facing forward).
5.
Mark the route for the outlet pipework.
Note!
The outlet elbow should be
sited above the mixer and on the right
or left, as site dictates.
6.
Remove the plasterboard and/or
brick work to a minimum depth of
60 mm.
Securing
Bracket