28
Re-assembly
11.
Identify which is the hot inlet to the shower control body, and align the Thermostatic
cartridge accordingly. Carefully push the Thermostatic cartridge back into the
body, checking that the 2 cartridge inlet port seals remain in place, and locate
cartridge lugs into body slots.
12.
Carefully align and then tighten the head nut;
do not overtighten
(max. torque
2.5 Nm (1.85 lbf ft)).
13.
Align and refit the body shroud and temperature knob assembly, so that the
markings will be visible to the user.
14.
Restore hot and cold supplies and check for any leaks.
15.
The maximum temperature will now need resetting; refer to
COMMISSIONING.
Thermostatic Cartridge Removal
Figure 8
Temperature Knob Assembly
Locking Screw
3 mm A/F Hexagonal Wrench
Temperature Hub
Removal Clip
Inlet Port Seals
Head Nut
Thermostatic
Cartridge
Assembly