13
(f) Carefully align and then tighten the headnut.
Do not
overtighten (maximum
torque 2.5 Nm (1.85 lbf ft)).
5.
Reversed inlets and top outlet
(Refer to Figure 4)
(a) Rotate the shower control 1/2 turn.
Note!
The inlet elbows may need repositioning (Refer to Installation).
6.
Complete
INSTALLATION
, if appropriate.
Reversed Inlets
Figure 3
Reversed Inlets and Top Outlet
Figure 4
C
H
C
H
Top Outlet
Figure 2
Standard
Figure 1
C
H
C
H
Note!
The red and blue markings on the cartridge will now not correspond with
the body markings, so to avoid future confusion remove the red and the blue
stickers from the cartridge.
(c)
Pull the Thermostatic cartridge free of the shower control.
(d)
Rotate the Thermostatic cartridge 1/2 a turn (this reverses the position of
the cartridge hot and cold inlets).
(e)
Carefully push the Thermostatic cartridge back into the shower control body.
Make sure that the 2 cartridge inlet port seals remain in place, and locate
the cartridge lugs into the body slots.