2.2.7. DI/DO
Tab. 2.6: Digital Inputs and Outputs
Signal
Description
Pin
Digital input (differential) - Positive - (P)
DI1+
1
Digital input (differential) - Negative - (N)
DI1-
2
Ground
GND
3
Digital Output 1
DO1
4
Digital Output 2
DO2
5
Ground
GND
6
Digital Input 2
DI2
7
Digital Input 3
DI3
8
Digital Outputs:
• Open drain output max. 50 VDC, 0.2 A
Isolated differential digital input:
• Input voltage difference (P-N) > 1.9 VDC Logic "H"
• Input voltage difference (P-N) < 1.1 VDC Logic "L"
• Maximum differential voltage 50 V
Digital inputs:
• Schmitt-triggered inverted input
• Pull below 1.1 VDC to activate (1.1 VDC / 1.9 VDC threshold hysteresis)
• Max. 50 VDC