Paradigm Installer/User Guide

Attaching Multiple Paradigm Units

1. Follow steps 1-6 of the Basic Install section.

2. Plug the 25-pin “D” connector of your computer interface cable into

any available channel port on the rear of your base Paradigm unit.

3. Plug the 15-pin video connector on the other end of the cable into the

port  labeled  on  your  first  cascading  Paradigm  unit.  Plug  the  PS/2
mouse connector, designated by a yellow band or mouse icon, into

the    port.  Plug  the  remaining  6-pin  miniDIN  keyboard  connector
into the 

 port. The 9-pin serial and 5-pin DIN connectors are not

used for cascading.

4. Repeat steps 2-3 for every cascaded Paradigm unit in your system.

5. Power-up your Paradigm unit(s) first, then all attached computers.

100-240V

     ,

 .1A

, 50/60 H

z

SETU

P

A

E

B

F

C

G

D

H

P

A

TENT PENDING

MADE IN USA

1

0

 !

US

ER

100-240V

     ,

 .1A

, 50/60 H

z

SETU

P

A

E

B

F

C

G

D

H

P

A

TENT PENDING

MADE IN USA

1

0

 !

US

ER

8

Advanced Install

Advanced Install

PS/2 KEYBOARD CONNECTOR

PS/2 MOUSE

CONNECTOR

CASCADING UNIT

BASE UNIT

VGA VIDEO

CONNECTOR

Summary of Contents for Paradigm

Page 1: ...Installer User Guide 274 Madison Avenue New York NY 10016 USA 212 679 0050 Fax 212 679 0040 www RackitTechnology com...

Page 2: ...Paradigm Installer User Guide...

Page 3: ...chines Corporation Microsoft and Kensington are registered trademarks of their respective companies Logitech Mouseman and Trackman are trademarks of Logitech Inc IntelliMouse is a trademark of Microso...

Page 4: ...d and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in...

Page 5: ...oubleshooting 34 D Problem Report 39 Chapter 5 Channel Scanning Choosing a Scanning Method 23 Setting the Scanning Order 24 Turning Scanning On and Off 24 Setting the Scanning Dwell Time 25 Scanning a...

Page 6: ...an equilateral triangle is intended to alert the user to the presence of uninsulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electr...

Page 7: ...parently without operator intervention and may be powered up one at a time or all at once When the power stabilizes a channel may be selected The first available channel is automatically selected upon...

Page 8: ...locking up and keeps you from losing time and data A built in scanning feature allows you to automatically monitor or scan your PCs without intervention When keyboard activity is detected scanning is...

Page 9: ...IntelliMouse Other manufacturers mice may operate with the Paradigm If you experience problems using an untested mouse contact Rackit Technical Support with the manufacturer and model number of the m...

Page 10: ...Paradigm Installer User Guide...

Page 11: ...herals 2 Locate your PS 2 keyboard VGA video monitor and PS 2 mouse 3 Plug your VGA monitor cable into the port on the back of your Paradigm in the user console section Plug your PS 2 keyboard cable i...

Page 12: ...rd connection and a 9 pin serial 6 pin miniDIN connector for a serial or PS 2 mouse connection The PS 2 mouse connector is designated by a yellow band or mouse icon Use only the keyboard and mouse con...

Page 13: ...ower cord into an appropriate AC wall outlet This outlet must be near the equipment and easily accessible to allow for unplugging prior to any servicing of the unit 7 Power up your Paradigm unit first...

Page 14: ...ated by a yellow band or mouse icon into the port Plug the remaining 6 pin miniDIN keyboard connector into the port The 9 pin serial and 5 pin DIN connectors are not used for cascading 4 Repeat steps...

Page 15: ...e mode For information on implementing password security see the Administrator Functions section of chapter 4 PCs may be powered up one at a time or all at once No operator intervention is required du...

Page 16: ...adigm are your PCs addresses Enter the letter A H for the PC you re selecting For cascaded systems enter the address of the base unit first Example You have a Paradigm unit cascaded from channel B of...

Page 17: ...keystrokes entered will be forwarded to the attached computer until you exit Command Mode Next enter the address Addr for the channel you wish to select Press Enter to accept the new channel The follo...

Page 18: ...hot key sequence to the default 1 Press and hold down the Num Lock key 2 Press and release the minus key on the numeric keypad 3 Release the Num Lock key CM H2 Enter Changes the hot key sequence to th...

Page 19: ...dministrator should login as Admin Root or Administrator If the user name is valid the password window will appear Type your password and press Enter This will bring up your Channel List If there is n...

Page 20: ...o the top or bottom of the list with the home and end keys Press a letter while in the main OSD Window and the Highlight Bar moves to the first channel name beginning with that letter Press the letter...

Page 21: ...ng the Paradigm select the Reset Standard Mouse Keyboard option from this menu for a PC with a standard mouse driver or Reset Wheel Mouse Keyboard if you are using a PC with a Microsoft IntelliMouse d...

Page 22: ...for another cascade level type N and press Enter Press Esc at any point to exit this operation without adding the channel Adding New Channels with a cascaded unit 1 Select Add channel from the Channel...

Page 23: ...wish to delete in the main OSD Window 2 Press the Control key twice or type Alt M to access the Command Menu 3 Select Channel maintenance from the Command Menu 4 Choose the Delete channel option 5 Typ...

Page 24: ...d displays the name of the selected channel This window can be individually configured for each channel in your system The characteristics of the ID Window can be changed from the Channel Maintenance...

Page 25: ...onfigured independently The default time is set for 5 seconds 1 From the main OSD Window press the Control key twice or type Alt M to access the Command Menu 2 Select Channel maintenance from the Comm...

Page 26: ...mode simply delete the administrator password When the administrator password is enabled user passwords must also be entered or the switch will not be completely secure The default for users is no pa...

Page 27: ...assword is not case sensitive 5 Repeat entry of the password for confirmation CAUTION Security is enabled once the password has been created Store a copy of your password in a safe place You should no...

Page 28: ...ing of all attached servers in the channel list For each server choose a level of access for this user by selecting one of the function keys listed on the screen F5 for no access F6 for video only or...

Page 29: ...ys to scan through the channels in your Paradigm system either sequentially or alphanumerically Scanning sequentially allows you to view each of your active channels in the order that they are attache...

Page 30: ...3 Press Enter By keyboard hot key sequence System Administrator or non secure mode only The following key sequences control scanning 1 From the main OSD Window press the Control key twice or type Alt...

Page 31: ...mmand Menu 4 Choose the option Alpha Scan Dwell Time 5 Enter a number between 0 255 seconds Enter 0 to skip a channel during scanning For Sequential Scanning 1 From the main OSD Window press the Contr...

Page 32: ...equentially through all attached servers Note that with sequential scanning you will pause at every active channel regardless of whether that channel has been added to the channel list or not In secur...

Page 33: ...e Temperature 4 20 C to 122 50 C Input Power 8 0 W Operating Voltage 100 240 VAC Power Frequency 50 60 Hz Supported Hardware Computer IBM PC AT PS 2 and 100 compatibles Video Modes VGA SVGA XGA XGA II...

Page 34: ...radigm units to be used as the slave unit 2 Connect your VGA monitor cable to the port labeled on the back of this unit Next connect your keyboard to the port labeled on the same unit 3 Locate the pow...

Page 35: ...Unit Configuration 8 Change the unit configuration selection to option 3 Paired Slave 9 Press Enter Enter Enter Enter Enter to save your selection Next press the Esc Esc Esc Esc Esc key repeatedly to...

Page 36: ...VGA connectors and one 15 pin female VGA connector It also contains a 9 pin male serial cable 2 Plug a male VGA connector into the port labeled on each of the Paradigm units 3 Connect the female VGA...

Page 37: ...for Use only the keyboard and mouse connectors that are appropriate for Use only the keyboard and mouse connectors that are appropriate for your PC and leave the others unconnected your PC and leave t...

Page 38: ...ord from the wall outlet servicing the unit Always disconnect the power cord from the wall outlet servicing the unit Always disconnect the power cord from the wall outlet servicing the unit Always dis...

Page 39: ...4 Change the unit configuration to Option 1 Tiered 5 Press Enter Enter Enter Enter Enter to save your selection and Esc Esc Esc Esc Esc to exit OSD 6 Disconnect the serial and video cables from both P...

Page 40: ...ve this manual with you when you call along with a copy of your invoice giving the date purchased and other identifying data Symptom Action No status light Verify unit is turned on Check power cable I...

Page 41: ...OSD screen Verify that a computer is attached to that channel If the problem persists contact Rackit Technical Support No video Verify that the video cable between the PC and the Paradigm is correctl...

Page 42: ...all Verify that the mouse is plugged into the correct PS 2 computer channel port on the back of the Paradigm Verify that the mouse is PS 2 style and a supported brand See the Product Overview chapter...

Page 43: ...ain If the problem persists contact Rackit Technical Support Keyboard is inoperable after Try changing the keyboard scan set for that channel switching channels by using the keyboard command sequence...

Page 44: ...me circuit Use only Rackit supplied cable Rackit warranties do not apply to damage resulting from user supplied cable Do not use a 2 wire extension cord in any Rackit product configuration Test AC out...

Page 45: ...er Service Call Number if one has been issued Paradigm Part Serial Revision Name and Model of Monitor Name and Model of Keyboard Name and Model of Mouse Firmware Summary results from AV command see ma...

Page 46: ...ttached to your Paradigm system Problem Description Include all affected ports exact nature of problem troubleshooting steps taken etc Port Computer Manufacturer Model BIOS Manufacturer Revision Opera...

Page 47: ...tructed and miswired cabling can diminish video quality and damage equipment Rackit manu factured cabling is built to high quality standards utilizing overall braided shield to comply with FCC emissio...

Page 48: ...Paradigm Installer User Guide 590 077 001 REV B...

Reviews: