VBOX 3iSL User Guide
Page 39 of 49
01/12/2011
No communication with PC
If the red LED on the front of the VBOX 3i SL is not illuminated then there is no power to the unit; check that battery contains adequate charge or, if using a
cigar lighter, check internal cigar lighter fuse.
Check that the correct COM port has been selected in VBOXTools
Check that no other programs are using the same COM port.
Disconnect the power to the VBOX 3i SL then reconnect it.
VBOX Manager
‘Please Wait No CAN’
Do you have the port that the VBOX Manager is connected to (either SER or CAN) dedicated to the Racelogic CAN bus?
Check the port the VBOX File Manager is connected to has CAN termination set.
VB3i SL Locked up
If the VB3i SL unit is unresponsive, perform a GPS coldstart and then power cycle your unit.
If problems still persist contact
for further assistance.
COM Port Unavailable
The computer may have been started with a different VBOX 3iSL connected to it; disconnect the VBOX, restart the computer then reconnect the VBOX.
Another software package installed on your computer may have reserved the COM port.
No Data is logged to the VBO file
Check satellite reception. Loss of reception may prevent data from being logged to the card (dependent on logging mode).