1260-12 User Manual
EADS North America Defense
Module Specification 1-1
Test and Services, Inc.
©
1993
Chapter 1
MODULE SPECIFICATION
Introduction
The 1260-12 Relay Actuator Module is a 20-channel double-pole,
double-throw switching module.
Specifications
User
Connector
Quick
Disconnect
Maximum Switchable Voltage
220 VDC, 250 VAC
(Terminal-Terminal or Terminal-Chassis) RMS
Maximum Switchable Current
2 A DC or RMS
Maximum Switchable Power
60 W DC, 62.5 VA AC
Per
Channel
DC Performance
Path
Resistance
200
m
Ω
at 2A
Isolation
>10
9
Ω
AC Performance
Capacitance
Open
Channel
<25
pF
Channel-Chassis
<25
pF
Hi-Lo
<50
pF
Bandwidth, (-3 dB, 50
Ω
Termination)
35 MHz (typical)
Insertion Loss, (50
Ω
Termination)
<.20 dB at 100 kHz
<.25
dB
at
1
MHz
<0.5
dB
at
10
MHz
Crosstalk, (50
Ω
Termination)
<-75 dB at 100 kHz
<-60
dB
at
1
MHz
<-40
dB
at
10
MHz