Safety 

Technology 

& Innovation 

 

• 

2 start behaviors possible: 

-  Manual start 

-  Automatic start 

• 

Short circuit and earth fault monitoring 

• 

Up to PL d, SILCL 2, category 3 

• 

It is not allowed to open the device, tamper with the de-

vice or bypass the safety devices. 

• 

All relevant safety regulations and standards are to be 

observed. 

• 

The overall concept of the control system in which the 

device is incorporated must be validated by the user. 

• 

Failure to observe the safety regulations can result in 

death, serious injury and serious damage. 

Correct Use 

SR101A is the low-cost emergency stop safety relay with which 

machines and systems can be safely switched off by disconnect-

ing  the  power  supply.  Internal  fault  monitoring  takes  place 

during restarting via the start button. 
Applications  for  the  SR101A  include  single  or  dual-channel 

emergency stop circuits and guard monitoring on machines and 

systems. 

Features 

• 

2 safe, redundant relay outputs 

• 

Connection of: 

• 

    -  Emergency stop buttons 

    -  Safety switches 

    -  Non-contact safety switches 

• 

Single and dual-channel operation possible 

• 

Feedback loop for monitoring downstream contactors or 

expansion modules 

• 

Cyclical monitoring of the output contacts 

• 

Indication of the switching state via LED 

 

Function 

The  emergency  stop  safety  switching  device  SR101A  is 

designed  for  safe  isolation  of  safety  circuits  according  to      

EN 60204-1 and can be used up to safety category 3, PL d 

according to EN ISO 13849-1. 
The internal logical system closes the safety contacts when 

the start button is pressed. 
If  the  safety  switch  is  opened,  the  positively  driven  safety 

contacts are opened and safely switch the machine off. It is 

ensured  that  a  single  fault  does  not  lead  to  a  loss  of  the 

safety  function  and  that  every  internal fault is  detected by 

cyclical  self-monitoring  no  later  than  when  the  system  is 

switched  off  and  switched  on  again.  Only  a  fault  in  the 

safety  switch  itself  is  not  detected.  This  must  be  checked 

regularly as part of a maintenance plan. 

Electrical  

Connection 

• 

When the 24 V version is used, a control transformer 

according to EN 61558-2-6 or a power supply unit with 

electrical isolation from the mains must be connected. 

• 

External fusing of the contacts (4 A slow-blow or 6 A 

quick-action or 10 A gG) must be provided. 

• 

A maximum length of the control lines of 1000 meters 

with a line cross section of 0.75 mm

2

 must not be ex-

ceeded. 

• 

The line cross section must not exceed 2.5 mm

2

• 

If the device does not function after commissioning, it 

must be returned to the manufacturer unopened. Open-

ing the device will void the warranty. 

Installation 

As per EN 60204-1, the device is intended for installation in 

control  cabinets  with  a  minimum  degree  of  protection  of 

IP54. It is mounted on a 35 mm DIN rail according to DIN 

EN 60715 TH35. 

Safety  

Precautions 

• 

Installation and commissioning of the device must be 

performed only by authorized personnel . 

• 

Observe the country-specific regulations when installing 

the device. 

• 

The electrical connection of the device is only allowed to 

be made with the device isolated. 

• 

The wiring of the device must comply with the instruc-

tions in this user information, otherwise there is a risk 

that the safety function will be lost. 

Fig. 1 Block diagram SR101A 

Fig. 2  Installation / removal 

Fig. 3  Connections 

A1:  

Power supply 

A2 : 

Power supply 

S11:  

DC 24V control voltage 

S21: 

Control line 

13-14: 

Safety contact 1 

23-24: 

Safety contact 2 

(not for the plug-in terminals) 

SR101A 

User Information for SR101A  